06/20/05

Addendum Sheet for the 200SL Digital Indicator


200SL only

NAME/CODE

DESCRIPTION

CODE /

VALUE

A10

Auto Power
Off Period

Selects the auto off time period in minutes:

“Off” = Disabled (Always ON)

Off, 1, 2, 3,
5 , 8, 10,
15, 20, 30

A11

Hold Mode
Enable

Activates the “Hold” mode where weight of the object on the
platform is frozen on the display. This is used in conjunction with
the Motion Band setting (F5) and the Percentage Hold setting
(F12) to capture an unstable load, such as livestock.

Automatic Mode: Automatically locks weight on the display at
stable. The percentage hold setting unlocks the held reading and
relocks on the new weight in both increasing and decreasing
weight values.

Manual Mode: Press the NET/GROSS key before applying
weight. When load is stabilized, the display will hold the weight
reading until the NET/GROSS key is pressed again. The
percentage hold setting unlocks the held reading and relocks on
the new weight in increasing weight values only.

Peak Hold Mode: Pressing the UNITS key toggles between
normal or peak hold mode. The display updates as the load
increases but not as the load decreases. The value shown on the
display is the maximum weight applied to the scale at any period
of time.

“0” = Disabled, “1” = Automatic, “2” = Manual, “3” = Peak Hold

0

1

2

3

A12

Handshaking
Enable

Enables hardware handshaking for Print Ticket Mode. Valid only
when A6 is set to “1”.

“0” = Disabled Handshaking

“1” = Enable Handshaking

0

1

A13

Print Header

Tells MP-20 printer to print the header information. Valid only
when A6 is set to “1”

“0” = Do NOT Print Header

“1” = Print Header

0

1



F12

Percentage
Hold

Allows you to select the percentage (of the displayed held value)
of weight change before the scale automatically unlocks the held
reading and relocks on the new weight.

5, 10 , 20,
50, 75, 100