Service hints, Technical service, Cleaning and maintenance – Desa Tech CCL3018PTA/NTA User Manual

Page 24

Advertising
background image

www.desatech.com

113097-01D

24

2. Inspect burner, pilot and primary air inlet holes

on injector holder for dust and dirt (see Figure

36).

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figure 37). With the unit

off, lightly blow air through the air inlet hole. You

may blow through a drinking straw if compressed

air is not available.

CLEANING AND

MAINTENANCE

Continued

Figure 36 - Injector Holder On Outlet

Burner Tube

Burner Tube

Primary Air
Inlet Holes

Injector Holder

Figure 37 - Pilot Inlet Air Hole

Burner Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs,

page 16, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

MAIN BURNER

Periodically inspect all burner flame holes with

the heater running. All slotted burner flame holes

should be open with yellow flame present. All

round burner flame holes should be open with a

small blue flame present. Some burner flame holes

may become blocked by debris or rust, with no

flame present. If so, turn off heater and let cool.

Remove blockage. Blocked burner flame holes

will create soot.

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• for propane/LP units, propane/LP gas supply

may be low

You may feel your gas pressure is too low. If

so, contact your local propane/LP or natural gas

supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Productsʼ Technical Service Department

at 1-866-672-6040. When calling please have your

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal service web site at www.desatech.com.