General troubleshooting – Chauvet SCORPION GVC User Manual

Page 22

Advertising
background image




Page 22 of 26

Scorpion™ GVC/RVM/RGY User Manual (Rev. 02k)

General Troubleshooting

Symptom

Possible Cause

Possible Action

Circuit breaker
or fuse keeps
blowing

• Excessive load on the circuit

• Make sure that the total load

does not exceed 80% of the
breaker or fuse nominal current

• Short circuit along the power

lines

• Check the power lines and

power cords

Product does not
power up

• No energy on power outlet

• Check power outlet
• Change to another outlet

• Loose or damaged power cord

• Check the power cord

• Blown fuse

• Replace blown fuse with a good

one of the same type and rating

• Internal problem

• Send product for repair

Fixture does not
respond to DMX

• Wrong starting address on the

fixture

• Set the correct starting address

on the fixture

• Use the right fader(s) on the

controller

• Wrong DMX personality on the

fixture

• Set the correct DMX fixture’s

personality

• Assign the faders accordingly

• Wrong polarity setting on the

DMX controller

• Change the signal polarity on

the controller

• Loose or damaged DMX cable

• Check the DMX cable before

the faulty unit

• Internal problem

• Send product for repair

Intermittent DMX
Problems

• Signal cables are not DMX

compatible

• Replace non DMX cables with

true DMX cables

• Interference with AC or radio

signals

• Keep DMX cables away from

AC wires or radio equipment

• DMX cable too long

• Install an optically coupled DMX

amplifier right before the fixture
with intermittent problems

• Too many fixtures connected

• Install an optically coupled DMX

amplifier after unit #32

• Terminator not connected

• Install a terminator, as indicated

in the “DMX Primer” section.

If you still experience problems after trying the above solutions, contact
CHAUVET® Technical Support.