INSIDE GLAZE

SILL FLASHING INSTALLATION

1. ANCHORS DESIGNED TO TWIST IN.

2. SPACE ANCHORS MAX. 4" FROM

EACH SIDE OF MULLION.

3. BENT LEG ALWAYS TO EXTERIOR.

4. NOTE: STAKE ANCHORS TO PREVEN

T

HORIZONTAL MOVEMENT.

ANCHORS MUST FACE EXTERIOR

AS SHOWN.

INTERIOR

A SHIM UNDER FLASHING

IS THE PREFERRED METHOD

FOR BEST THERMAL RESULTS.

FLASHING ANCHORS MUST

BE CAP SEALED.

SEALANT

FG-3217

FG-3000-FP-4

PART #: 7947

FG-3000-FP-3

PART #: 7948

FG-3000-FP-11

PART #: 7979

1/4" NOM.

SEAL WITH A NON-SKINNING,

NON-HARDENING SEALANT.

FILL BREAK IN FLASHING

AND UNDER SPLICE.

NOTE: SILL FLASHING

SHOULD BE LEVEL AND

MAKE SURE IT IS NOT TILTED

TOWARD THE INTERIOR.

FLASHING SPLICE