Outsideglz-frm-install, Outside glaze frame installation – Oldcastle BuildingEnvelope FG-3000 User Manual

Page 9

Advertising
background image

OUTSIDE GLAZE

FRAME INSTALLATION

FG-1122 X 4" LONG

(PART SOLD IN STOCK LENGTHS.)

1. ASSEMBLY WITHOUT FLASHING

IS NOT RECOMMENDED.

2. DO NOT ANCHOR WALL THRU

VERTICAL LEG OF FLASHING.

SEALANT

ACCESS HOLE AT ALL ANCHOR LOCATIONS.

(SIZE DETERMINED BY ANCHOR.)

DRILL CLEAR HOLE IN FLASHING THOUGH

ANCHOR CLIP. THEN INJECT SEALANT INTO

HOLE IN FLASHING AND UNDER ANCHOR CLIP.

ANCHOR SIZE AND FREQUENCY SHOULD BE DETERMINED BY STRUCTURAL REQUIREMENTS.

SILL ANCHOR FG-2000-FP-3 AND HEAD ANCHOR FG-2122 SHOULD BE LOCATED SO THAT

THE ANCHOR IS NOT MORE THAN 4" FROM EACH SIDE OF THE MULLION.

FG-2000-FP-3

PART #: 7944

FG-2188

PVC PROFILE

USED TO IMPROVE

INSTALLATION OF

BACKER ROD AND

PERIMETER SEALANT.

(OPTIONAL)

CLEAR HOLE

(SIZE DETERMIMED BY ANCHOR.)

8

JULY 2011

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

F L U S H G L A Z E S E R I E S 3 0 0 0 I N S T A L L A T I O N M A N U A L