Vermont Casting ST967 User Manual

Fuel conversion kit, Instructions for intrepid direct vent gas stove

Advertising
background image

Fuel Conversion Kit

Instructions
for Intrepid Direct Vent Gas
Stove

Kits:
Natural to LP: 20012921
LP to Natural: 20012910

WARNING!

The installation of this conversion kit must only
be undertaken by a qualified gas appliance
installer.

This kit is designed for conversion of the Intrepid Direct
Vent Gas Stove Models INDVR Series.
Tools required: 5/32” (4 mm) Allen wrench, 3/8” and
1/2” open end wrenches, needlenose pliers.
Kit contents: Pilot orifice, injector orifice, conversion
label.

Conversion Precautions

Allow unit to cool completely before beginning conver-
sion. Before proceeding, turn control knob on valve to
OFF and turn gas supply to OFF. Turn OFF any electric-
ity that may be going to the appliance.

Conversion Procedure

1. Remove stove front. Lift stove front up and then

swing bottom out and away to disengage from the
stove body. (Fig. 1)

2. Undo the right and left latches at the top of the glass

frame. (Fig. 2)

3. Pull the top edge of the glass and frame assembly

away from the firebox face. Place the assembly out
of the way on a flat, padded surface such as a coun-
ter protected by a towel.

4. Remove the logset from the firebox.

ST967

Intrepid install front

7/07

INTREPID

ST967

Fig. 1 Remove the stove front. (Top vent shown)

ST208

glass swivel latch

12/99

ST208

Fig. 2 Release the latches to remove the glass frame.

Valve Conversion
1. Turn control knob to the OFF position, and shut off

the gas supply to the valve.

2. Allow the valve to cool to room temperature.
3. Remove the black protection cap by hand. (Fig. 3)
4. Insert a 5/32” or 4 mm Allen wrench into the hexago-

nal key-way of the screw (Fig. 4), rotate it counter-
clockwise until it is free and extract it.

��

��

�����
������������
����

Figure 3

��

��

�����
������������
����

Figure 4

20012973 7/07 Rev. 0

Advertising