Pilgrim Pressure Regulators Type 70 User Manual

Type-70 high fl ow regul ators, Regulator options & accessories, Option ordering matrix

Advertising
background image

REGULATOR OPTIONS &

ACCESSORIES

NON-RELIEVING

Used in applications where it is desirable to relieve pressure
downstream of the regulator, for some constant flow applica-
tions, and where the gas flowing through the regulator must not
escape at the regulator. Non-relieving regulators should not be
used for low or no flow applications.

CORROSIVE RESISTANT EPOXY FINISH

An epoxy paint applied to the body and dripwell of the regulator
exterior surfaces to provide increased corrosion resistance.

TAPPED VENT

Allows installation of plumbing to capture exhaust air.

MOUNTING BRACKET

Steel (dichromate finish) bracket for side mounting.

PRESSURE GAUGE

Dual scale 2 in. (50.8 mm) gauges. Ranges include 0-30 psig
(0-200 kPa), 0-60 psig (0-400 kPa), 0-100 psig (0-700 kPa) and
0-160 psig (0-1100 kPa). When specified with regulator, the
correct range will be supplied.

TAMPER-RESISTANT COVER

An aluminum tubular cover placed over a slotted head adjusting
screw and screwed onto the bonnet of the regulator with a
wrench. Prevents ordinary hand adjustments.

LOW BLEED

Reduces steady-state air consumption by approximately 50%.

CHECK VALVE

Allows quick dumping of output line pressure through the
supply air line when the supply is shut down.

LT 0805 3m 2/04

SALES & APPLICATIONS

(800) 727-5646 fax: (304) 387-4417

www.mar shbellofr am.com

IMPORTANT NOTICE: Our recommendations, if any, for the use of this product are based on tests believed to be reli-
able. The greatest care is exercised in the selection of our raw materials and in our manufacturer, no guarantee or war-
ranty, express or implied, is made as to such use or effects incidental to such use, handling or possession or the
results to be obtained, whether in accordance with the directions or claimed so to be. The manufacturing expressly
disclaims responsibility therefor. Furthermore, nothing contained herein shall be construed as a recommendation to
use any product in conflict with existing laws and/or patents covering any material use.

USA

EUROPE

State Route 2, Box 305

9 Castle Park, Queens Drive

Newell, WV 26050

Nottingham NG2 1AH, UK

800-727-5646 or (304) 387-1200

Tel +44 (0) 115 993 3300

FAX (304) 387-4417

Fax +44 (0) 115 993 3301

[email protected]

[email protected]

OPTION ORDERING MATRIX:

Add three digits from table below to end of part number.

OPTION

2

3

5

6

7

8

9

10

11

2

Non-Relieving

002 032 052 062 072 082 092

112

3

Sq. head Adj. Screw

003 053 063 073 083

103 113

5

Epoxy Coating

005 065 075 085 095 105 115

6

Tapped Vent

006 076 086 096 106 116

7

Mounting Bracket

007 087 097 107 117

8

Pressure Gauge

008 098 108 118

9

Tamper-Resistant Cover

009 109 119

10 Low Bleed

010 110

11 Check Valve

011

TYPE-70 HIGH FL

OW REGUL

ATORS

Port

Size

Set Point Range

Part Number (NPT)

BAR

psig

T-70

960-129-000

1/4"

0-0.1

0-2

960-174-000

3/8"

0-0.1

0-2

960-162-000

1/2"

0-0.1

0-2

960-130-000

1/4"

0-0.7

0-10

960-131-000

3/8"

0-0.7

0-10

960-163-000

1/2"

0-0.7

0-10

960-089-000

3/8"

0-2.1

0-30

960-090-000

1/4"

0-2.1

0-30

960-159-000

1/2"

0-2.1

0-30

960-091-000

3/8"

0.1-4.1

1-60

960-092-000

1/4"

0.1-4.1

1-60

960-160-000

1/2"

0.1-4.1

1-60

960-093-000

3/8"

0.1-10.3

2-150

960-094-000

1/4"

0.1-10.3

2-150

960-161-000

1/2"

0.1-10.3

2-150

960-152-000

1/4"

0.2-13.8

3-200

960-153-000

3/8"

0.2-13.8

3-200

960-164-000

1/2"

0.2-13.8

3-200

T-70BP

960-191-000

1/4"

0-0.1

0-2

960-192-000

3/8"

0-0.1

0-2

960-194-000

1/4"

0-0.7

0-10

960-195-000

3/8"

0-0.7

0-10

960-197-000

1/4"

0-2.1

0-30

960-198-000

3/8"

0-2.1

0-30

960-200-000

1/4"

0-4.1

0-60

960-201-000

3/8"

0-4.1

0-60

960-203-000

1/4"

0-10.3

0-150

960-204-000

3/8"

0-10.3

0-150

OPTIONS

= option is available

s = standard

Type

70

70BP

2

Non-Relieving

3

Knob

s

s

Sq. Head Adj. Screw

5

Epoxy Coating

6 Tapped

Vent

7

Mounting Bracket

8

Pressure Gauge

9

Tamper - Resistant Cover

10 Low Bleed

11 Check Valve

Advertising