Problem

Cause

Remedy

The unit is heating but the

indicator light is not on

1. The indicator bulb has

blown

1. Replace the indicator light: call a

service agent or qualified technician

1.Faulty element(s)

1.Call service agent or qualified

technician

2.Operation of thermostat

2. Ensure that the thermostat is set

correctly, also ensure the dial is not

spinning on the thermostat and giving the

wrong reading

Indicator light is on but the

unit is not heating

3.Faulty thermostat

3. Call service agent or qualified

technician

1.No water in the pan

1. Fill the pan to the indicated level

(between Min and Max)

2. Thermostat setting

2. Ensure that the thermostat is set

correctly, and the dial is not spinning

Slow heat up

3. Faulty element(s)

3. Call service agent or qualified

technician

Please ensure:

*There is correct power supply.

*The machine is plugged in correctly and power is switched on.

*The thermostat dial has been turned on.

Note: All Cecilware products are tested prior to packing.

Compliance

Cecilware products have undergone strict product testing in order to comply with regulatory standards

and specifications set by international, independent, and federal authorities.

As testimony to such compliance, Cecilware products carry the following marks/symbols:

4

Advertising
This manual is related to the following products: