CANOGA PERKINS L351 ESU User Manual

Quick start guide l351 esu

Advertising
background image

Quick Start Guide

L351 ESU

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com

P/N 6942580 Rev A

Page 1 of 8




Overview

This document provides instructions for installation and initial configuration of the Canoga
Perkins model L351 ESU (Ethernet Service Unit).

The EdgeAccess L351 Ethernet Service Unit

is a managed Ethernet and Fast Ethernet Compliant device that supports native 10Mbps and
100Mbps Transparent LAN extension circuits. The L351 offers 10/100 auto sensing or software
configurable User Interface and a variety of optical network interfaces. The L351 is modular and
hot swappable with a common form factor to mount in Canoga Perkins’ Carrier Class Universal
Chassis System (UCS) as well as a variety of Customer Premise Enclosures (CPE).

Parts List

1 x L351-xxxx
1 x UCS 1000 or UCS 1002 chassis
1 x UCS 1001 chassis
1 x UCS 1230 BAM (Bus Access Module)
1 x Model 1020-2100 (management access CPE) or 1030-2200 (unmanaged CPE)
1 x EIA-232 serial cable (straight)
1 x EIA-232 to DB9 converter (Canoga Perkins p/n CRJ-D9F-10)

Step 1: Unpacking

Unpack the L351 and check the unit for damage. If the unit is damaged, contact Canoga Perkins’
Tech Support line, (800) 360-6642, and ask for an RMA.

Step 2: Module Set Up

Before installation into a chassis or enclosure, you must verify the application in which the L351
will be used, i.e. 10Mbps or 100Mbps Ethernet, managed or non-managed etc. The application
may require setting the dip switches located at the rear of the L351. If the unit is to be installed in
the UCS 1030 enclosure, set the L351 to the desired configuration using Table 1 as a reference.
Otherwise, the L351 can be configured through software to the desired configuration when
installed in the UCS 1000, 1001, 1002 or 1020.

Figure 1. L351 Switches and Default Setting

Advertising