Housing unit, O camera housing control board, Air filter – Panasonic AW-PH650 User Manual
Page 10: Top cover open/close bolts (x2), O heater, Ventilating fan, Grip, O l/f connector, Wiper blade, Wiper unit
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Parts and theirfunctions
■ Housing unit
©
© ©<D
<The inside of housing>
o
©
©
© o
o
Camera housing control board
Connect the supplied camera cable.
©Air filter
Air is taken in through the air filter. Replace it when it is
clogged up.
(Wheneverthe airfilter needs replacement, askthe store
where you purchased the product to do the job.)
©Top cover open/close bolts (X2)
Loosen using the supplied Allen key, open the top cover.
o Heater
When the controller's H/F switch is at ON, the heater will
come on whenever the temperature inside the camera
housing drops.
©Ventilating fan
When the controller's H/F switch is at ON, the fan will
come on whenever the temperature inside the camera
housing rises.
Depending on the temperature, the fan operates at the
high or low setting.
Use the switch at the ON setting because a high
camera temperature will adversely affect the camera's
performance.
©Grip
Used to carry the camera housing.
o
l/F connector
Connect this to the l/F connector on the main unit.
©Wiper blade
Replace the wiper blade when it can no longer wipe off
waterdrops well.
How to replace it: Raise the blade at the centre, pull it up
and off, and fit a new blade in its place.
After replacing the blade, checkthat the
two rods holding the wiper blade are
parallel to the glass surface.
(Whenever the wiper blade needs
replacement, askthe store where you
purchased the product to do the job.)
©Wiper unit
Used to wipe off waterdrops during or after a rain. The
wiper operates when the WIP switch on the controller is
pressed on.
© Defroster
The anti-fogging heater is vapor-deposited. It turns on
when the controller's DEF switch is set to ON, and it is
turned off by the thermo switch when the temperature
rises above the rating.
©Housing mounting raiis
Align the rails with the housing mount frame which is
installed on the rotary arm of the main unit, and slide the
housing along the rails.
©Housing mounting screw hoies (X2)
Use these holes to secure the housing using the housing
securing bolts provided with the housing mount frame
which has been installed on the rotary arm of the main
unit.
9(E)