Replacing the agitator brushes, Warning – Panasonic QUICKDRAW MC-V5117 User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

A

WARNING

Electrical Shock or Personal Injury Hazard.

Disconnect the electrical supply before servicing or cleaning the unit. Failure to do
so could result in electrical shock or personal injury from cleaner suddenly starting.

REPLACING THE AGITATOR BRUSHES

1 When to replace the agitator brushes

The agitator brushes should be replaced when the brushes

are worn Brushes should be checked by holding a card

across the bottom plate (see illustration) If the bnstles on the

agitator assembly

do not

touch the card you

should

replace

all the brushes for best cleaning results

2 How to replace the agitator brushes

Place the vacuum cleaner handle in the low position (See the

Handle Adjustments section ) Remove the lower plate as

outlined in the Removing/lnstalling the Lower Plate section

After the lower plate is removed, carefully lift up the agitator

assembly until it clears both sides of the nozzle housing

While holding the agitator assembly up. remove the belt

Carefully remove the E-ctip from the agitator shaft using a

small screwdnver and then remove right end cap Pull the

agitator shaft out the opposite end of the a^tator and puli or

pry out the belt pulley and agitator holder The brushes can

now be replaced easily Push each brush as shown in the

illustration until

It IS

free from the brush holder Install the

new brushes by reversing the procedure Reinstall the

agitator holder, belt pulley, making sure they are completely

and firmly inserted, the agitator shaft, end cap, and E-clip in

the reverse order of removal See the exploded view below

for correct assembly of all parts

Note

Take care not to bend the agitator shaft Do not mis­

place the small E-dip Be carefull when removing and reinstal­

ling

It

from the shaft end, as it can easily get away from you

3 To replace the agitator assembly

Place the belt over the belt pulley on the agitator unit

(NOTE

There is a place for the belt to fit on one end of the agitator

assembly only) After assembling the belt, place the agitator

assembly back into the nozzle housing, aligning each end cap

After completing the assembly, rotate the brush, turning it
by hand to assure that it rotates smoothly and the part is assembled correctly

Replace the lower plate as outlined in the Removing/lnstailing the Lower Plate section