CIR INFRARED HEATER

WWW.STIEBEL-ELTRON-USA.COM

INSTALLATION

INSTALLATION

Mounting Bracket for CIR 400-2 O

8

8

M8

Ø8

1/2˝

(13)

1/2

˝

(13)

1 1/4

˝

(32)

1 1/4˝

(32)

1 9/16˝

(40)

1 9/16˝

(40)

13 3/16˝

(97)

7 1/2˝

(190)

7 1/2

˝

(190)

1 9/16˝ (40)

5 3/8˝ (137)

9. Attach the heater bracket to the mounting bracket (outermost

hole), using the bolt, lock washer and nut supplied. Tighten

securely.
10. The bracket attached to the top of the heater allows rotation up

to 45° on the short axis by loosening the attachment bolt.
11. Once heater position is established, tighten all nuts and bolts at

mounting and heater bracket connections to maintain the heater

in a secure and stable position.
12. Read and follow all warnings, and the following section on

Operation to enjoy safe operation of the heater.

9.7 Power supply

DANGER Electrocution!
Carry out all electrical connection and installation
work in accordance with all national, state and local
building code.

DANGER Electrocution!
Each 240 V heater must be wired directly to a circuit
with a timer switch and the proper size breaker and
wire gauge.

DANGER Electrocution!
Do not plug models CIR 200-2 O or CIR 400-2 O into
a wall outlet.

The specified voltage on the nameplate must match
the voltage at the circuit breaker panel.

Electrical connection must be performed by a qualified electrical

tradesperson. Installation must conform with the latest edition

Electrical Code ANSI/NFPA N0 70 in the U.S.A. and PART 1 CSA

C22.1 in Canada.

9.7.1 CIR 150-1 I and CIR 150-1 O
Plug heater into a properly grounded wall outlet connected to a

120 V, 60Hz, 15 Amp copper wire circuit that is properly grounded

and controlled by a timer switch.
9.7.2 CIR 200-2 O
Using 12 AWG copper wire, connect the heater to a 240 V, 60Hz,

15 Amp circuit breaker that is properly grounded and controlled

by a timer switch.
9.7.3 CIR 400-2 O
Using 12 AWG copper wire, connect the heater with a timer switch

to each of two independent 240 V, 60Hz, 15 Amp circuit breakers

that are each properly grounded.