Installation installation, Connection box, Connection box heater body – STIEBEL ELTRON SunWarmth CIR 400-2 O User Manual

Page 15

Advertising
background image

WWW.STIEBEL-ELTRON-USA.COM SUNWARMTH

CIR INFRARED HEATER|

15

EN

G

L

IS

H

INSTALLATION

INSTALLATION

4. Remove 2 Phillips screws that fasten the connection box face

plate in place:

5. Disconnect electrical supply cord spade connectors from

terminals:

6. Loosen 2 screws in terminal block that connect the red heat

lamp wires in place. Remove ends of red wires from terminal

block.
6A. Loosen plastic collar on Liquid Tight Connector that secures

red wires to connection box:

7. Slide power cord retainer plate from heater body (top surface

of heater):

8. Loosen plastic collar on second Liquid Tight Connector that

secures red wires through connection box end plate.
» Slide red wires out of connection box.
» Set connection box aside:

9. Remove end plate from heater: 6 Phillips screws fasten the

heater body end plate in place:

Connection
box

Connection
box

Heater
body

Advertising
This manual is related to the following products: