Power up sequence in qdr-ii sram, Power up sequence, Dll constraints – Cypress CY7C1312BV18 User Manual

Page 19

Advertising
background image

CY7C1310BV18, CY7C1910BV18
CY7C1312BV18, CY7C1314BV18

Document #: 38-05619 Rev. *F

Page 19 of 29

Power Up Sequence in QDR-II SRAM

QDR-II SRAMs must be powered up and initialized in a
predefined manner to prevent undefined operations.

Power Up Sequence

Apply power and drive DOFF either HIGH or LOW (all other
inputs can be HIGH or LOW).

Apply V

DD

before V

DDQ

.

Apply V

DDQ

before V

REF

or at the same time as V

REF

.

Drive DOFF HIGH.

Provide stable DOFF (HIGH), power and clock (K, K) for 1024

cycles to lock the DLL.

DLL Constraints

DLL uses K clock as its synchronizing input. The input must
have low phase jitter, which is specified as t

KC Var

.

The DLL functions at frequencies down to 120 MHz.

If the input clock is unstable and the DLL is enabled, then the
DLL may lock onto an incorrect frequency, causing unstable
SRAM behavior. To avoid this, provide1024 cycles stable clock
to relock to the desired clock frequency.

Figure 3. Power Up Waveforms

> 1024 Stable clock

Start Normal

Operation

DOFF

Stable (< +/- 0.1V DC per 50ns )

Fix High (or tie to VDDQ)

K

K

DDQ

DD

V

V

/

DDQ

DD

V

V

/

Clock Start (Clock Starts after Stable)

DDQ

DD

V

V

/

~ ~

~~

Unstable Clock