2 rackmount installation, Rackmount installation -4, Section 3.4.2 – Cabletron Systems 2H23-50R User Manual

Page 30: Describes the rackmount installation, Figure 3-1

Advertising
background image

Chapter 3: Installation

3-4

2H23-50R/2H33-37R User’s Guide

Figure 3-1

Tabletop or Shelf Installation

3.4.2

Rackmount Installation

To install the device in a 19-inch rack, note that the device is shipped with
a rackmount kit containing the rackmount brackets, mounting screws, and
a strain-relief bracket for cable management.

Guidelines for the Rackmount Installation

The installation site must be within reach of the network cabling and meet
the requirements listed below:

Ensure that an appropriate grounded power receptacle is located
within seven feet of the location.

Maintain a temperature of between 5

°

C (41

°

F) and 40

°

C (104

°

F) at

the installation site with fluctuations of less than 10

°

C (18

°

F) per hour.

!

CAUTION

To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in) at the left, right,
and rear of the device.

WARNING

Before installing the device

into a rack, ensure that the rack

supports the device(s) without compromising the stability of the
rack. Otherwise, personal injury and/or equipment damage
may result.

22861-06

A = 15 cm (6 in)
B = 57.2 cm (22.5 in)
C = 53 cm (21 in)

C

B

A

D

D = 213 cm (7 ft)

6

5

CONN 1

CONN 3

CONN 4

CONN 2

CONN 4
CONN 3
CONN 2
CONN 1

CONN 4
CONN 3
CONN 2
CONN 1

12

1

12

1

12

1

12

1

2H23-50R

COM

PWR
CPU

RESET

10

100