Chassis alarms – Cisco 12000/10700 V3.1.1 User Manual

Page 551

Advertising
background image

18-3

Cisco 12000/10700 v3.1.1 Router Manager User Guide

OL-4455-01

Chapter 18 Fault Management

Cisco 12000/10720 Router Trap Support

Informational

Normal

Chassis Alarms

Table 18-2

provides information on traps that result in alarms raised against the chassis object.

Table 18-2 Monitored Attributes for a GRP Module

Trap

Alarm Description

Severity

Clears

Cold start

Cold Start: Agent reinitializing; configuration
may have changed.

Major

Cold start

RPR+ Switchover

RPR+ Cold Start: Agent reinitializing;
configuration may have changed

Major

RPR+ Switchover

RPR Switchover

RPR Cold Start: Agent
reinitializing;configuration may have changed

Major

RPR Switchover

Redundancy Framework (RF)
Progression

RF Notification: RF state has changed. Active
Unit: <slot-no> State: <RF-state>. Peer Unit:
<slot-no> State: <RF-state>

Major

Redundancy
Framework (RF)
Progression

Warm start

Warm Start: Agent reinitializing; configuration
is unaltered.

Major

Warm start

Authentication Failure

Authentication Failure

Major

Authentication
Failure

Voltage Normal

Voltage higher Chassis, normal, <value> mV

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Voltage Warning

Voltage higher Chassis, warning, <value> mV

Warning

Critical, Shutdown,
Warning, NotPresent

Voltage Critical

Voltage higher Chassis, critical, <value> mV

Critical

Critical, Shutdown,
Warning, NotPresent

Voltage Shutdown

Voltage higher Chassis, shutdown, <value> mV Critical

Critical, Shutdown,
Warning, NotPresent

Voltage Not Present

Voltage higher Chassis, notPresent, <value> mV Informational

Critical, Shutdown,
Warning, NotPresent

Temperature Normal

Slot <no>: Switch Fabric Card Hot Sensor,
normal, <value> degree celsius

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Temperature Warning

Slot <no>: Switch Fabric Card Hot Sensor,
warning, <value> degree celsius

Warning

Critical, Shutdown,
Warning, NotPresent

Temperature Critical

Slot <no>: Switch Fabric Card Hot Sensor,
critical, <value> degree celsius

Critical

Critical, Shutdown,
Warning, NotPresent

Temperature Shutdown

Slot <no>: Switch Fabric Card Hot Sensor,
shutdown, <value> degree celsius

Critical

Critical, Shutdown,
Warning, NotPresent

Temperature Not Present

Slot <no>: Switch Fabric Card Hot Sensor,
notPresent, <value> degree celsius

Informational

Critical, Shutdown,
Warning, NotPresent

Advertising