Cisco 12000/10700 V3.1.1 User Manual

Page 552

Advertising
background image

18-4

Cisco 12000/10700 v3.1.1 Router Manager User Guide

OL-4455-01

Chapter 18 Fault Management

Cisco 12000/10720 Router Trap Support

Note

Temperature traps include the affected slot in the alarm description.

As can be seen from the table, Cisco EMF alarms may be cleared by other alarms. The general pattern
is that an alarm clears alarms of the same or higher severity. All other alarms should be cleared manually.

Fan Normal

Fan Tray 1, normal

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Fan Warning

Fan Tray 1, warning

Warning

Critical, Shutdown,
Warning, NotPresent

Fan Critical

Fan Tray 1, critical

Critical

Critical, Shutdown,
Warning, NotPresent

Fan Shutdown

Fan Tray 1, shutdown

Critical

Critical, Shutdown,
Warning, NotPresent

Fan Not Present

Fan Tray 1, notPresent

Informational

Critical, Shutdown,
Warning, NotPresent

Power Supply Normal

Power Supply 1, normal

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Power Supply Warning

Power Supply 1, warning

Warning

Critical, Shutdown,
Warning, NotPresent

Power Supply Critical

Power Supply 1, critical

Critical

Critical, Shutdown,
Warning, NotPresent

Power Supply Shutdown

Power Supply 1, shutdown

Critical

Critical, Shutdown,
Warning, NotPresent

Power Supply Not Present

Power Supply 1, notPresent

Informational

Critical, Shutdown,
Warning, NotPresent

BGP Connection Established

BGP Connection Established with Peer
<peer-IP-Address>, Connection is in
<peer-state> State

Normal

BGP Connection
Established, BGP
Connection Broken

BGP Connection Broken

BGP Connection Broken with Peer
<peer-IP-Address>, Connection is in
<peer-state> State

Major

BGP Connection
Broken

FlashDeviceChange

A Flash Device has been inserted or removed
from the chassis

Informational

FlashDeviceChange

Table 18-2 Monitored Attributes for a GRP Module (continued)

Trap

Alarm Description

Severity

Clears