18-5

Cisco 12000/10700 v3.1.1 Router Manager User Guide

OL-4455-01

Chapter 18 Fault Management

Cisco 12000/10720 Router Trap Support

Interface Alarms

Table 18-3

provides information on traps that result in alarms raised against interface objects.

Syslog Traps

Note

Care should be taken when using the Syslog alarm feature since there are multiple possible severity
levels that can be activated which can result in large trap volumes. This can affect Cisco 12000/10720
Router Manager performance (for example, when opening an Event Browser) and hinder effective
monitoring because of the high numbers of alarms that will be raised. It is advised that only the high
severity traps are monitored by default, switching on others if more information is required.

Cisco IOS can be configured to send Syslog traps to a designated server. There are eight levels of Syslog
information which are mapped into four categories of Cisco EMF alarm severity. Syslog specific data is
inserted into the Message portion of the Cisco EMF alarm. In all cases, alarms are raised against the
Chassis object.

Table 18-5

summarizes the severity mapping between trap and alarm:

Table 18-3 Alarms Raised Against Interface Objects

Trap

Alarm Description

Severity

Clears

Link down

Interface:<interface_name> Down,Operational
Status:Down, Administrative Status:Down
Reason:Administratively down

Major

Link down

Link up

Interface:<interface_name> Up, Operational
Status:Up

Normal

Link up, link down

Flow Created

A New Flow has been generated for
<rsvp-FlowIndex> from Link <interface
index>

Normal

Flow Created, Flow
Lost

Flow Lost

Flow Lost for <rsvp-FlowIndex> from Link
<interface index>

Informational

Flow Lost

PVC Failed

Total <no_of_failed_PVCs> PVCs are not up on
ATM Interface <interface
Index>

Informational

PVC Failed

Table 18-4 Alarms Raised Against SRP Side Interface Objects for Wrap Status

Trap

Alarm Description

Severity

Clears

SRP Ring Wrapped

SRP Ring Wrapped

Major

SRP Ring Wrapped

SRP Ring Restored

SRP Ring Restored

Normal

SRP Ring Wrapped,
SRP Ring Restored

Advertising