Electrical termination cable color codes, Model numbers – Hardy HI LPRE05 Shear Beams User Manual

Page 33

Advertising
background image

OPERATION AND INSTALLATION MANUAL

Page 27

Step 2.

Use a megohmmeter and measure the
resistance between all five wires tied
together and the load cell metal body.

• The measured value should be 5,000

megohms or more.

WARNING

WHEN USING A MEGGER DO NOT EXCEED
50 VOLT RANGE.

• If the sensor fails this test remove the

ground wire and test with only the four
live leads.

• If the sensor passes the test an insulation

problem in the cable is most likely.

Step 3.

Replace the load cell if the cell fails both
tests.

Electrical Termination
Cable Color Codes

The cable is 6 conductor, shielded (floating) and 20
feet in length.

EXC+

Red

EXC -

Black

SHIELD

Yellow

C2+

Gray

C2-

Violet

SIG +

Green

SIG -

White

Model Numbers

NOTE:

The -43F/B/S indicates a stainless steel load sensor
with stainless steel mounting hardware. For galva-
nized mounting hardware use -45 F/B/S

Capacity

Model #

Model #

Model #

LBS

Kn

Fixed Assembly

Bumper Assembly

Slider Assembly

1,125

5

HI HLPS1125-43F

HI HLPS1125-43B

HI HLPS1125-43S

2.25K

10

HI HLPS2.25K-43B

HI HLPS2.25K-43B

HI HLPS2.25K-43S

TABLE 5: MODEL NUMBERS & CAPACITIES