Inovonics FA209 User Manual

Fa209, Fa209 billtrap operation, Fa209 installation

Advertising
background image

FA209

Frequency Agile

!

!

!

!

900MHz

BilltrapTransmitter

Installation Instructions

02109C

FA209 Billtrap Operation

The FA209 billtrap transmitter is designed to be used in retail and banking cash drawers.
When the trigger bill is removed, the billtrap will send an alarm transmission. The user can
opt for instant or delayed transmission of the alarm.

Hook and loop mounting square

Billtrap

Important Notes

!" These products are designed to be installed and maintained

by professional security technicians.

!" Products, unless specifically noted, are intended for indoor use.
!" Manually test all products regularly.

© 1995 Inovonics Wireless Corporation

315 CTC Blvd, Louisville CO 80027

(800) 782-2709

FAX (303)939-8977

E-mail: [email protected]

www.inovonics.com

02109C.DOC LIT-FA209-INSTALL

hc:8-Aug-01

FA209 Installation

1. Remove

bottom

plate.

2. Set

DELAY SELECTOR

jumper.

3. Program

transmitter.

4. When programming is complete, disconnect cable and re-attach bottom plate.

5. Mount the billtrap in the cash drawer using hook and loop square provided, or other means.

6. Place trigger bill in the billtrap.

FA209

Billtrap Transmitter

3V

3V

RESET BUTTON

TAMPER BUTTON

PROGRAMMING

HEADER

DELAY SELECTOR

FA209 Specifications


Program

contacts:

N/O

EOL:

No

Internal

Contacts:

No

Typical battery life:

1-2 yrs @ 60-second* check-in

Battery (BAT609):

3.0V lithium CR2450N, quantity 2

(Batteries always supervised)

Dimensions:

6.188" x 2.625" x .750"

* NOTE: The FA209 doubles the programmed check-in interval, resulting in extended battery life. A unit programmed

for 60-second check-in will actually send a check-in round every 120 seconds.

Delay Selector Settings

Placement of the selector jumper determines whether or not the transmitter will delay before
sending an alarm. The delay lets users quickly replace the trigger bill if it has inadvertently
been removed from the billtrap. With the jumper in the delay position, the alarm will be
delayed for 7 to 13 seconds. NOTE: Instant response time will be 0 to 2.4 seconds.

10 SECOND DELAY

INSTANT ALARM

FA209 Programming

1. When prompted to plug in transmitter, connect cable from programming device to

programming header on transmitter.

2. Press reset button on transmitter.

3. When programming is complete, disconnect cable.

NOTE: The FA209 retains programming data in non-volatile memory. It does not
require re-programming after loss of power. Install new batteries and press reset
button to re-initialize the transmitter and restore programming.

ATTENTION: Test the transmitter at least once each week. See warranty.

Advertising