102

Information Codes

NOTE

1 After identifying the problem and verifying the recommended action, if the information Codes

keep reoccurring or for help on Information Codes that appear on your machine but are not
listed above, please contact your local Panasonic Authorized Dealer.

456

Unit received a confidential document or was
requested to be polled of a confidential document
under any of following conditions.
1. Not enough space in memory to receive the

confidential document.

2. Confidential Mailbox is full.
3. While printing received document(s).

Unit was requested to relay a document.

1. Print a File List and check the contents.
2. Wait until unit finishes printing.

494

Communication error occurred while receiving.

Check with the other party.

--

495

Telephone line disconnected.

Check with the other party.

--

501/502 Communication error occurred using the internal V.34

Modem.

Check with the other party.

--

540/541

542

543/544

Communication error occurred while transmitting.

1. Reload the document(s) and send again.
2. Check with the other party.

--

550

Telephone line disconnected.

Check with the other party.

--

554/555 Communication error occurred while receiving.

Check with the other party.

--

570

A Remote Diagnostic or Firmware Update command
was received, while the Remote Diagnostic
parameters are not set.

Check the settings of the Fax Parameters No.
51 and 52.

35

580

Sub-Address transmission to a unit that has no Sub-
Address function.

Check the remote station.

581

Sub-Address Password transmission to a unit that has
no Password Sub-Address function.

Check the remote station.

601 ADF Door was opened during ADF transmission. Close the ADF Door and send again. 104

623

No document loaded on the ADF.

Reload the document(s) and send again.

--

630

Redial was not successful due to a busy line.

Reload the document(s) and send again.

--

631

During dialling, STOP was pressed.

Reload the document(s) and send again.

--

634

Redial was not successful due to no response from
the called station or wrong number dialed.
Note: If busy tone was not detected, the machine
will only redial once.

Check the telephone number and send again.

--

638

Power failure occurred during the communication.

Check the power cord and plug.

18

870

Memory overflow occurred while storing document(s)
into memory for transmission.

Transmit document(s) without storing into
memory.

47

887

Power failure occurred.

96

Info.

Code

Meaning

Action