Costar 9RV User Manual

Model 9rv, Owner’s manual

Advertising
background image

OWNER’S MANUAL

Model 9RV

Carbon Monoxide Alarm for Recreational Vehicle Use

ATTENTION: PLEASE READ, FOLLOW AND SAVE

CSA 6.19-01

Dear New COSTAR® 9RV Owner,

Congratulations as you have taken steps to help insure the health and life safety of you and your family. We are

proud to offer you our unique, patented CO Sensor technology that detects CO in a mannersimilar to the human

body’s response. The COSTAR® 9RV is an ideal and low-cost way of warning you of both the acute and chronic

effects of CO poisoning.

Please read this owner’s manual carefully so you will have a better understanding of the effects of CO poison-

ing and the COSTAR® 9RV Alarm, as we work together pursuing a safer, healthier indoor air quality for us all.

To your good health and safety,

Mark Goldstein, Ph.D.

President

Quantum Group Inc.

WARNING: Failure to replace this product by the “REPLACE BY DATE” printed on the alarm cover

may result in death by Carbon Monoxide poisoning. Replace By Date is six (6) years from date of

manufacture.

1.0 WHAT YOU SHOULD KNOW ABOUT CO

Carbon monoxide (CO) is an insidious poison. It is a colorless, odorless and tasteless gas. It is a cumulative

poison. Even low levels of CO have been shown to cause brain and other vital organ damage in unborn infants

with no effect on the mother.

The following symptoms may be related to CARBON MONOXIDE POISONING and should be discussed

with ALL members of the household:

MILD EXPOSURE:

Headaches, running nose, sore eyes, nausea, vomiting, fatigue (often described as “flu”-like symptoms);

MEDIUM EXPOSURE:

Severe throbbing headache, dizziness, drowsiness, confusion, fast heart rate;

EXTREME EXPOSURE:

Unconsciousness, convulsions, brain damage, cardio respiratory failure, death.

Many cases of reported CARBON MONOXIDE POISONING indicate that while victims are aware they are

not well, they become so disoriented they are unable to save themselves by either exiting the building or calling

for assistance. Also, young children and household pets may be the first affected. Your CO alarm is designed to

detect the toxic CO fumes that result from incomplete combustion, such as fuel burning appliances (e.g. space

heater, furnace, water heater, range, oven, clothes dryer), or other sources of combustion (e.g. kerosene-burning

stove or heater or gas log fireplace) or internal combustion engines (e.g. automobile exhaust). Furthermore,

installation of this device is not a substitute for proper installation, use, and maintenance of fuel-burning appli-

ances, including appropriate ventilation and exhaust systems.This carbon monoxide alarming device is designed

to detect carbon monoxide gas from ANY source of combustion. It is NOT designed to detect smoke, fire, or

any other gases.

CAUTION: This alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monox-

ide gas may be present in other areas.

WARNING: This product is intended for use in ordinary indoor locations of family living units. It is not

designed to measure compliance with commercial or industrial standards, such as Occupational Safety and

Health Administration (OSHA). This device is designed to protect individuals from the acute effects of carbon

monoxide exposure. It will not fully safeguard individuals with specific medical conditions. Individuals with

medical problems may consider using warning devices which provide audible and visual signals for carbon

monoxide concentrations under 30 ppm. If in doubt, consult a medical practitioner.

2.0 WHAT YOU SHOULD DO IF THE ALARM SOUNDS

WARNING: Actuation of your CO alarm indicates the presence of carbon

monoxide (CO), which can KILL YOU. If alarm signal sounds (flashing

RED LED and pulsating horn):

For users in the United States, follow the protocol in steps 1 through 4 below:

1) Operate reset/silence button;

2) Call your emergency services (_____ - _______) [fire department or 911];

3) Imediately move to fresh air – outdoors or by an open door or window. Do a

head count to check that all persons are accounted for. Do not reenter the prem-

ises nor move away from the open door/window until emergency services

responders have arrived, the premises have been aired out, and your alarm

remains in its normal condition.

4) After following steps 1–3, if your alarm reactivates within a 24-hour period, repeat

steps 1–3 and call a qualified repair technician (_____ - _______) to investigate

the sources of CO from fuel burning equipment and appliances, and inspect for

proper operation of this equipment. If problems are identified during this inspec-

tion, have the equipment serviced immediately. Note any combustion equipment

not inspected by the technician and consult the manufacturer’s instructions, or

contact the manufacturers directly, for more information about CO safety and this

equipment. Make sure motor vehicles are not, and have not been, operating in an

attached garage or adjacent to the residence.

For users in Canada, follow the protocol in steps 1 and 2 below:

1) Imediately move to fresh air – outdoors or by an open door or window. Check

that all persons are accounted for. Do not re-enter the premises or move away

from the open door/window until the emergency services responders have

arrived, the premises have been aired out, and your alarm remains in its normal

condition;

2) Call your emergency services (_____ - _______) [fire department or 911]; If

“service” signal sounds (RED LED flashes and horn beeps every 30 seconds),

contact the manufacturer for troubleshooting and/or instructions to return the

unit: Quantum Group, Inc. Customer Service: 1-800-432-5599

2.1 IMPORTANT CONSIDERATIONS

The 9RV has been designed and is warranted to operate for six years. Never disconnect the battery to silence

an alarm. The alarm will automatically sense when the level of CO in the air falls below the danger level. You

should stay outside the vehicle in fresh air until the alarm is silenced. When the alarm sounds, do not stand too

close to the alarm. The sound produced by the alarm is loud because it is designed to awaken a person in an

emergency. Prolonged exposure to the alarm at a close distance may be harmful to your hearing.

WARNING:TEST ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE, BEFORE EACH

TRIP, AND AT LEAST ONCE PER WEEK DURING USE.

3.0 DEVELOPING YOUR OWN CO SAFETY PLAN

This CO alarm can quickly alert you to the presence of CO - it cannot prevent toxic CO emissions. Please note

that there are hazards against which CO detection may not be effective, such as natural gas leaks or explosions.

The ultimate responsibility for protection against toxic CO gas rests solely on you. Installing CO alarms is just

the first step in protecting your family from toxic CO poisoning. We also suggest that you create an effective,

comprehensive safety program as outlined below.

3.1 Install CO alarms properly following the instructions in this manual.

3.2 Develop a family escape plan and practice it with your entire family, especially small children.

• Draw a floor plan of your RV and find two ways to exit. There should be one way to get out of your

RVwithout opening the door.

• Make sure that all occupants know what the CO alarm signal means and how they must be prepared to leave

the RV by themselves if necessary.

• Decide on a meeting place a safe distance from your RV and make sure all occupants understand where they

should go and wait if there is a dangerous CO condition.

• Conduct CO safety drills at least every 6 months to make sure that everyone, even small children, know

what to do in order to escape safely.

• Know where to go to call the Fire Department from outside your RV.

4.0 IMPORTANT: WHAT YOUR CO ALARM CAN AND CANNOT DO

4.1 This unit is designed to detect carbon monoxide (CO) entering its sensing chamber. It does not sense

combustible gas (such as natural gas, propane or butane), heat, smoke or flames.

4.2 NOTE: This CO alarm is designed for use within a single recreational vehicle. The alarm may not provide

early warning for occupants if it is placed outside of the recreational vehicle, such as on outside porches.

4.3 When properly located, installed, and maintained, this CO alarm is designed to provide early warning of devel-

oping poisonous CO conditions at a reasonable cost. This alarm monitors the air, and when it senses CO, it

activates its built-in alarm. It can provide precious time for you and your family to escape from your RV before

CO can seriously injure or kill. However, such an early warning is possible only if the alarm is located,

installed, and maintained as specified in the Owner’s Manual.

4.4 If your RV has an interior room divider or door it is recommended to place a CO alarm on both sides of the

divider or door. If the alarm is located outside of a bedroom, it may not wake up a sound sleeper, especially if

the bedroom door or divider is closed or only partly open.

WARNING: The COSTAR® Model 9RV CO Alarm is not designed for marine use.

5.0 INSTALLING THE COSTAR® 9RV ALARM FOR RECREATIONAL VEHICLE USE

Figure 1: Suggested Mounting Locations for RVs

5.1 RECOMMENDED MOUNTING LOCATIONS

One of the most important considerations in any CO alarm system is the location of the alarms. Statistics of the

National Fire Protection Association (NFPA) show that most of the fatal CO occurrences happen at night while

people are sleeping. Early warning of CO is best achieved by the correct installation of CO alarms. Placement

of an alarm in a garage may cause an alarm due to CO from engine exhaust.

5.2 Put a CO alarm in a central location inside the vehicle, near sleeping areas. A closed door can block particulate

smoke, but CO gas is likely to get through.

5.3 This CO alarm may be mounted on the wall or ceiling.

5.4 WALL LOCATION: Mount alarm at least 3 feet (usually 5-6 feet) from the floor.

5.5 CEILING LOCATION: Alarm should be mounted as close as possible to the center of a hallway or room. If

this is not possible, the edge of the alarm should be at least 4 inches from any wall.

5.6 LOCATIONS TO AVOID

• Within 5 feet (1.5m) of any cooking appliance

• Near an open window or door, because the fresh air entering the opening may delay CO from reaching the

alarm

• In damp or very humid areas or next to bathrooms with showers. Install detectors at least 5 feet (1.5 meters)

away from bathrooms

• Locations where normal ambient temperatures are not met. Normal ambient temperature limits are 40°F to

100°F (4.4°C to 37.8°C)

Note: Most batteries are not rated below -20°C or above 54°C

• Accommodation spaces should be well ventilated when household cleaning supplies or similar contaminants

are stored or used.

5.7 CONDITIONS WHICH CAN RESULT IN TEMPORARY CO SITUATIONS:

5.7.1 Excessive spillage or reverse venting of fuel burning appliances caused by:

i) Outdoor ambient conditions, such as wind direction and/or velocity, including high gusts of wind,

and insufficient draft in the vent pipes (cold/humid air with extended periods between cycles);

ii) Negative pressure differential resulting from the use of exhaust fans;

iii) Simultaneous operation of several fuel burning appliances competing for limited internal air;

iv) Loose vent pipe connections from fuel-fired appliances such as clothes dryers, furnaces, or water

heaters;

v) Obstructions, or unconventional vent pipe designs that can amplify the above situations;

vi) Poorly designed or maintained chimneys and/or vents;

5.7.2 Extended operation of unvented fuel-burning devices (range, oven, fireplace, etc.);

5.7.3 Temperature inversions that can trap exhaust gasses near the ground; and

5.7.4 RV, truck or car idling in an open or closed attached garage, or near a home.

6.0 INSTALLATION INSTRUCTIONS PLEASE READ CAREFULLY

CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE!

6.1 Select proper location

6.2 A mounting plate is provided on the back of the alarm. Remove the mounting plate from the back of the alarm

by holding the mounting plate and twisting the alarm in the direction indicated by the “OFF” arrow on the

alarm cover.

6.3 To insure aesthetic alignment of the alarm with the hallway or wall, the UP ARROW on the mounting plate

must be:

A) Parallel with the hallway walls when ceiling mounting

B) Pointed upward when wall mounting

C) See steps A & B in figure 2

!

!

!

Advertising