Channel Plus H218 User Manual

Channelplus enclosures

Advertising
background image

16” On Center

Enclosure

Attach enclosure using 4 screws.

Either from mounting tabs

or inside holes.

18

for H218

36

for H236

54

1/8”

1/8”

1/8”

for H254

14

3/8“

Mounting the enclosure

Use the mounting tabs when

mounting the enclosure between

the studs and using 1/2”

wallboard.

Mounting in existing wallboard or

surface mounting

Remove the mounting tabs.

Grab the tabs with

pliers and rock back

and forth to remove.

Wallboard

Stud

Enclosure

1/8”

When using other than 1/2”

wallboard, remove the mounting tabs

and mount the enclosure to protrude

1/8” beyond the wallboard surface.

H218 18” enclosure

H290 AC outlet accessory

ChannelPlus Enclosures

H236 36” enclosure

Mounting the H290 AC outlet accessory

The H290 accessory brings AC power

inside the H218, H236 or H254

enclosure. The H290 gives the

installer a clean, UL approved location

to mount power adaptors. Mount the

H290 to either the upper right or upper

left corner of the enclosure using the

four #6 screws provided. Installation

of AC outlets should be done only by a

qualified electrician.

1/2” knockouts for 120VAC

The H290 provides space for 4

standard duplex receptacles.

Wires should exit the H290 using

the grommets provided. The

grommets may be cut as shown.

Remove paint shield and save.

Route cabling into enclosure.

After cabling is routed, reverse

paint shield and return it to the

enclosure to protect cabling.

Installing cables

Grommet

OEM

AC ADAPTOR

Part no.: 123-456

U L

Remove knockouts as needed

and line holes with grommets provided

If H290 is installed, fold flaps on the

paint shield to bend the shield over

the H290 AC outlet accessory.

An old electrician’s trick

When hanging a heavy cabinet cover,

insert nails through the mounting holes

on the cover. Guide the nails into the

mating holes on the enclosure and let

the cover hang from the nails while you

attach the screws. (We’ve included two

of these sophisticated devices for your

assistance.)

Installing the cover

1

2

3

1) Hook from the top

2) Swing into place

3) push button to lock

OpenHouse modules attach from the top

ChannelPlus model H616

Telephone Master Hub (4 lines x 6 phones)

Telephone Master Hub (4 lines x 6 phones)

Telephones

Telephones

From

Telco

From

Telco

RJ31X

RJ31X

Out

Out

Expansion

Ports

Expansion

Ports

R

T

R

T

4

R

T

R

T

3

R

T

R

T

2

R

T

R

T

1

H290 installs in either of 2 locations

Grounding the cabinet

When used with model H290 accessory, the grounding lug on the

H290 is used. No separate ground lug is provided on the H218,

H236 or H254. The user must install ground lugs as necessary.

H254 54” enclosure

Advertising