Note: Check to make sure the right float switch is being used for the right application.

Normally Open - float switches are open while hanging “down” and will close on a rising

liquid level. Typically used for “empty tank” applications.

Normally Closed - float switches are closed while hanging “down” and will open on a

rising liquid level. Typically used for “filling tank” applications.
1. Determine desired cord tether length . See Figure 2.

2. Attach the Pipe Clamp at the desired location. See Figure 1. Adjust the tether length to achieve the desired

pumping range. Use Figure 2 as a guide and test system by filling tank and cycling the system to achieve actual

desired pumping range.

3. Tighten the clamp as tight as possible.

4. Electrical outlet must not be located in pump chamber. Electrical outlet voltage, piggyback plug voltage, and

pump voltage must match. Insert switch’s piggyback plug into outlet. Plug pump into piggyback plug and check

the system by allowing the system to cycle to insure proper operation.

Warning: Turn off all power when installing or adjusting unit.

Failure to turn off all power could result in serious injury or death!

Warning: End user to provide overcurrent protection rated at 240VAC

minimum, 15 Amps maximum.

Read instructions thoroughly. Check local codes and install to meet requirements.

Caution! Use Only

As A Guide,Actual

Testing Must Be

Performed To Obtain

Actual Pumping Range.

Caution! Minimum

Tether Length is 4”

Typical application shown

is for a pumping system

UL Listed. Suitable for

Water and Sewage.

Figure 1

Mounting Level

Electrical: 15 amp @ 120 VAC/240 VAC

Cord: SJOW-A flexible 14 gauge, 2 conductor Neoprene

Float Housing: High Impact PVC, 3.25” diameter x 4.55” length

Max Temperature: 140 degrees F.

Switch Configuration: Single Pole, Single Throw

4”

8”

5’

9”

6”

10”

7”

11”

8”

12”

9”

13”

10”

14”

11”

15”

12”

16”

13”

17”

14”

18”

15”

19”

16”

20”

17”

21”

18”

22”

Figure 2

Tether

Length

Pumping

Range

Big

Swi

tch

Pump

Flo

at

Specifications

Alderon Industries, LLC

P.O. Box 827

Hawley, MN 56549
Page 1 of 1

P/N 10384 Rev A

2/3/03

Phone: 218.483.3034

Fax: 218.483.3036

Big Switch

Pump Control

Operation, Maintenance

and Installation Manual

TM

PO Box 827 Hawley, MN 56549 (218) 483-3034 Fax (218) 483-3036 www.alderonind.com

Advertising