C&H Technologies VX405C User Manual

Vx405c m/ma module carrier, Applications, Specifications

Advertising
background image

C&H Technologies, Inc. • 445 Round Rock West Drive • Round Rock, TX 78681-5012

(512) 733-2621 • FAX (512) 733-2629 • www.chtech.com

Connectors:
• Each M/MA Module has its own

front panel and connectors.

Indicators:

MODID

SYSFAIL

M/MA Module Access (6)

Power:

+5V @ 1.3 A typical

Plus M/MA Power

+12V and –12V provided to the

M/MA Modules but not used

by the carrier.

Ordering Information

Description

Part Number

M/MA Mod. Carrier

11027050-0001

VXIbus Compliance

Complies with ANSI/IEEE Std 1014-
1987, IEC8921, and VXIbus Rev 1.4

A16/24/32:D8/16/32 Slave

SYSFAIL: Supported

Interrupts: ROAK, programmable
levels

BRX tied to BGX

TTL Triggers: Supports I/O
synchronous (SYNC) trigger
protocol

Form Factor: Size C

Applications

• Multiple instrument types in a

single VXI slot.

• Port customer interfaces from ITA

to a VXI slot

• VXI ATE “glue logic”

Specifications:

Number of M/MA Modules
Carried:
• Up to six(6). Each appears as an

independent VXI instrument.

Unique Logical Address for each
M/MA Module:
• Can be configured for sequential

numbering or Modulo-8 numbering
for Agilent Command Module
compatibility.

M/MA Module Triggers:
• TRIGA or TRIGB of M/MA module

may be connected to any VXI TTL
Trigger under software control.

M/MA Module Interrupts:
• Each module interrupt can have a

software programmable VXI IRQ
level.

M/MA Module Identification:
• M/MA IDENT function supported.

VX405C
M/MA Module
Carrier

The VX405C carrier provides the
mechanical and electrical interfaces
between the VXIbus and up to six
(6) VITA 12-1996 standard M/MA
Modules. The carrier provides VXI
register configuration and access to
the M/MA modules I/O space and
memory (if present). Each M/MA
module is controlled separately and
appears as a different Logical
Address in the VXI environment.
Over 200 M/MA modules are
available that can provide custom
interfacing to the unit under test
(UUT). Up to six (6) unique
instruments or interfaces may be
provided in a single VXI slot.

Advertising