Centurion MAGNUM M23/2000 User Manual

Martindale

Advertising
background image

024-001-750 MOD 8 11/05/07 Page 1 of 8 POWER UNITS

Centurion Safety Products Ltd. Howlett Way, Thetford, Norfolk, IP24 1HZ, UK

Tel. 0044 (0)1842 754266 Fax. 0044 (0)1842 765590

Martindale

USER INSTRUCTIONS:

MAGNUM P2/P3 POWERED RESPIRATORS

Models covered
Power Units :

M23/1000, M23/2000, M23/8500

Powered Respirator kits:

M23/1000/CB, M23/2000/CB, M23/8500/CB

(Power Unit, 8-hour Battery and UK Charger)

Available Headpieces:

See section 2 below

Before using the system it is essential that you read these instructions and ensure that the correct equipment has
been selected. Always be aware of the limitations of use of the equipment and that it is appropriate to the task.

1.

WARNINGS

If these instructions are not followed or the unit is used incorrectly the system may not offer protection to EN12941/42 or EN 146.
Power units offer NO protection unless a main filter(s) is fitted.
In a power off situation the headpiece offers no respiratory protection and rapid CO2 build-up and oxygen depletion may also result. This is an

abnormal situation.

Power off is an abnormal situation regardless of whether a full hood, half suit or mask is used.
At high work rates the pressure inside the headpiece may become negative at peak inhalation.
The system should not be used in oxygen deficient or oxygen enriched atmospheres.
The user must ensure that the nature of the hazard is identified and that the system offers an adequate level of protection.
This unit should not be used where the nature of the hazard is unknown.
This unit is NOT intrinsically safe and therefore should not be used in explosive atmospheres
Be aware that the hose protrudes from the back of the headpiece and take care to avoid snagging.
In high wind velocities the assumed protection levels may not be achieved.
The full hood and half suit provide no protection against impact to head, face or eyes.

Respiratory protection will be reduced unless the hood is correctly fitted and properly maintained.
Do not confuse the markings on any filter which relate to standards other than EN12941 or EN12942 with the classification of this device when
used with that filter. The classification for EN12941 will begin with "TH" and for EN12942 will begin with "TM". Filters should only be fitted to the
power unit, do not attempt to fit them directly to a hood or helmet.

2.

LIST OF PARTS , AVAILABLE HEADPIECES, APPROVALS / SPECIFICATION, NOMINAL AND ASSIGNED
PROTECTION FACTORS

kits

Power Unit

8 hr Battery

UK Charger

Standard Class

M23/1000/CB

(5)

M23/1000

M23P2/4B

M23P2/4BC

EN146

THP2

M23/2000/CB

(3)

M23/2000

M23SPB

M23UIC

EN12941

TH2/TH3

(6)

M23/8500/CB

M23/8500

M23SPB

M23UIC

EN12941/2

(4)

TH3/TM3

(1)

TH2

(2)

(1)

The M23/8500 and Full Facemask is approved with the full range of Martindale DIN 40 gas/combination filters.

(2)

The M23/8500 & TH2 headpieces are approved for use with the Fitta range of Combination Gas/Dust filters (M09A1P2) .

(3)

Optional 4 hour battery and charger available for the 2000 power units – M23P2/4B battery and M23P2/4BC charger.

(4)

All headpiece systems are to EN12941 or EN 146 with the exception of the Full facemask, which is to EN12942.

(5)

Note: Heavy Duty Battery M23HD4B and charger M23UIC are also available for use with the Magnum 1000 and will typically give durations of

12 hours+.

(6)

Note: Magnum 2000 only conforms to TH3 when used with M23P3/5 filters and M23LHF otherwise it conforms to TH2

(7)

Note: Nominal Protection factors of headpieces used with Magnum 1000 is 20

Nominal and Assigned Protection Factors for Headpiece/Power Unit kits
(Refer to Compatibility table below for suitable power units)

NPF

APF (UK)

Headpiece

code

dust

gases

(1,2)

dust

gases

(1,2)

Rigid Polycarbonate Visor with Saronex Hood

M23RVSN

50

(7)

50

20

20

Flip up Polycarbonate Visor

M23FUVN

50

(7)

50

20

20

Helmet with Flip-up Polycarbonate Visor

M23HFUV

50

(7)

50

20

20

High Temperature Helmet with Clear Triacetate Flip up Visor

M23HFUVHTT

50

(7)

50

20

20

High Temperature Helmet with Gold Polycarbonate Visor

M23HFUVHTGP

50

(7)

50

20

20

Automatic Welding Visor

M23AWSN

50

(7)

50

20

20

Fixed Shade Welding Visor

M23FSWVN

50

(7)

50

20

20

Lightweight P3 Tyvek F Hood

M23LHF

50/500*

50/500*

20/40*

20/40*

Full Hood

M23FH/8

500

-

40

-

Half Suit

M23HS/8

500

-

40

-

Full facemask with twin hose

M23FF

2000

2000

40

40

* Note NPF=500 & APF=40 when M23LHF is used with TH3P Filters (e.g. M23P3/5 or M23P3SL/6) and M23/2000 or 8500 otherwise the M23LHF
has NPF=50

(7)

& APF=20.

A detailed table showing the exact classifications and protection levels is given in the headpiece instructions (024-001-692) supplied with each
headpiece which must be read in conjunction with these instructions.