Braeburn 3220 Installer Guide User Manual

Detailed installer guide, Non-programmable thermostats, Remier

Advertising
background image

Detailed

Installer Guide

Non-Programmable Thermostats

1

Specifications 2 Installation and Wiring 3 Quick Reference

4 Installer Settings 5 System Testing

• Possible electric shock or damage to equipment can occur.

• Disconnect power before beginning installation.

Caution

This thermostat requires 24 Volt AC Power or 2 properly installed “AA” Alkaline

batteries for proper operation. When connecting 24 Volt AC Power the batteries may

be installed as a backup.

For use only as described in this manual. Any other use will void warranty.

3020 Single Stage Heat / Cool Conventional

or Heat Pump

3220 Up to 3 Heat / 2 Cool Heat Pump

Up to 2 Heat / 2 Cool Conventional

Warning

For installation by experienced service technicians only.

®

This thermostat is compatible with:

• Single stage heat / cool conventional and heat pump systems

• Conventional systems up to 2 stages of heating and 2 stages of cooling (3220 only)

• Heat pump systems up to 3 stages of heating and 2 stages of cooling (3220 only)

• 250 – 750 millivolt heating only systems

• 2 or 3 wire hydronic zone systems

Electrical and control specifications:

• Electrical Rating: 24 Volt AC

• 1 amp maximum load per terminal

• AC Power: 18 – 30 Volts AC

• DC Power: 3.0 Volt DC (2 “AA” Alkaline Batteries Included)

• Control Range: 45° – 90° F (7° – 32° C)

• Temperature Accuracy: +/- 1° F (+/- .5° C)

• Outdoor Temperature Display Range: -40° - 120° F (-40° - 49° C)

Terminations

• 3020: G, Rc, Rh, W1, O/B/V3, Y1, C, S1, S2

• 3220: G, Rc, Rh, W1/E/W3, W2, O/B/V3, Y1, Y2, C, L, S1, S2

1 Specifications

3020W-100-02

Model number is located on back of thermostat.

P

REMIER

S

ERIES

Advertising
This manual is related to the following products: