Braeburn 220550 User Manual

Flow-through bypass humidifier 12 gpd / 24v

Advertising
background image

33

1

PRECAUTION: The installer should be an experienced service technician. Disconnect electrical power before

beginning installation. Do not install where temperatures fall below 32 degrees F or where plenum temperatures

exceed 200 degrees F. When wiring into a multi-speed blower circuit see wiring diagrams.

FOR INSTALLATION ON A VERTICAL

PLENUM SURFACE OF ANY

FORCED AIR FURNACE

INSTALLER: PLEASE LEAVE INSTALLATION INSTRUCTIONS WITH HOME OWNER

2

220500

220550

FLOW-THROUGH BYPASS HUMIDIFIER

12 GPD / 24V

COPPER

TUBING

PLASTIC

TUBING

Connect by-pass pipe to collar and humidifier cabinet. Using

holes at top and bottom of side panel discharge, pierce 2

self tapping screws through by-pass pipe.

Mount the self tapping saddle valve on either a cold or a hot water

pipe. A side or top mount is best to avoid clogging from pipe

sediment. Connect 1/4” O.D. tubing to the saddle valve. Copper

tubing requires a brass compression nut and brass sleeve. Plastic

tubing requires a brass insert inside the tubing and a plastic sleeve

on the outside with a brass compression nut.
NOTE: DO NOT USE PLASTIC TUBING ON HOT WATER OR IN

CONTACT WITH ANY HOT PLENUM SURFACE OR DUCT.

INSTALLATION OF THIS SADDLE VALVE MUST MEET OR

EXCEED LOCAL CODES AND ORDINANCES.

4

Cut out center section of template and 6” hole. Humidifier is self

retaining. Slide top side in first, then slide chassis down. Level

chassis and install center screws. If by-pass pipe installs to

opposite side of chassis, bend clip on chassis, remove side

discharge, and reinstall discharge to opposite side of chassis.

Install remaining four corner screws.

HIGH BOY

COUNTER-FLOW

LOW BOY

RETURN AIR

RETURN AIR

RETURN AIR

WARM AIR

WARM AIR

WARM AIR

WARM AIR

DRAIN

DRAIN

DRAIN

1

2

The Braeburn model 220500/220550 may be installed on

either the supply or return plenum of a forced air handling

system. The 220500/220550 is reversible for installation with

bypass duct connections on the right or left side of the

cabinet. The outer dimensions of the cabinet are 13 1/2” wide

X 15” high X 9 1/2” deep. Select a location for the humidifier

that allows for service.

AIR CLEANER

INSTALLATION: The humidifier may be mounted with the 6"

outlet to the right or left by inverting the cabinet and reversing

the positions of the distributor trough and drain pan. The

humidifier may be mounted on the warm or return air plenum

with equal efficiency.

See Typical Installations.
ADDITIONAL MATERIALS THAT MAY BE NECESSARY:

1. 1/4" diameter plastic supply tubing or 1/4" copper

supply tubing for hot water applications

2. 6" diameter galvanized by-pass pipe

3. Electrical wire and wire nuts

4. Current sensing relay (Braeburn Model 229050 suggested)

5. #8 self piercing sheet metal screws