CEI 830 ULTRAK User Manual

01 2 3 (lap), Start lap 1 lap 2 lap 3 stop

Advertising
background image

SUITABLE MODEL: C5086 SIZE:A4 PD11121M

SOLAR STOP WATCH WITH TEMPERATURE

AND HUMIDITY

USER’S INSTRUCTIONS

FEATURES:

• Display month, date and day of the week
• Display time in 12 or 24-hour format
• LED backlight
• Daily alarm
• Heat index
• Dew point
• Temperature and humidity display
• 1/100-second stopwatch up to 10 hours
• 30 laps/splits memory records
• Countdown time function
• Water resistant
• Dual power

FUNCTION KEYS:

LAP/RESET key:

RECALL key:

MODE key:

START/STOP key:

LIGHT key:

PRODUCT DESCRIPTIONS

1.LCD
2.LAP/RESET key
3.RECALL key
4.MODE key
5.START/STOP key
6.Solar pannel
7.LIGHT key

DISPLAY SYMBOLS

NORMAL TIME MODE

1.Month
2.Day of the week
3.Time
4.Key tone
5.Date

ALARM TIME MODE

1.Normal time
2.Alarm time
3.Alarm icon
4.Alarm mode

TEMPERATURE AND HUMIDITY MODE

1.Humidity
2.Temperature

HEAT INDEX MODE

1.Heat index

DEW POINT MODE

1.Dew point

LAP MODE

1.Lap number
2.Current lap time
3.Stopwatch

SPLIT MODE

1.Split number
2.Current split time
3.Stopwatch

COUNTDOWN MODE

1.Countdown cycle times
2.Countdown time
3.Countdown timer

LAP TIME MEASUREMENT

Through this function, you can know the time spent in every lap. For
example, if you want to measure 3-lap time, do the following:
1.

Press the “MODE” key to enter the lap mode.

2.

Press the “START/STOP” key to start to measure the lap time.

3.

Press the “LAP/RESET” key for 3 times to record the time of lap
1, lap 2 and lap 3.

4.

Press the “START/STOP” key to save the measurement data.

5.

Press the “MODE” key to exit the lap time measurement mode.

Note:
1.

Press the “LAP/RESET” key to reset the time to “

before using this function.

2.

The following picture shows the way of lap time measurement.

In normal time mode, press it to turn on/off the key
tone.
In normal time, alarm time or countdown time
setting mode, press it to step the setting items.
In lap/split Recall mode, press it to check the
records upwards.
Press it to record the current lap/split number and
time during the lap/split time measurement period.
Press it to delete all lap/split time records after
the lap/split time measurement.

In normal time, alarm time or countdown mode,
press and hold it for 2 seconds to enter the time
setting mode.
In normal time, alarm time or countdown time
setting mode, press it to save the setting values.
In lap/split mode, press it to enter the lap/split Recall
mode only when you measured more than one-lap/
split time.

Press it to switch among normal time /
temperature and humidity / heat index / dew point
/ lap / split / countdown and alarm time mode.
In normal time, alarm time or countdown time
setting mode, press it to save and exit the setting
mode.

In normal time mode, press it to turn on/off the key
tone.
Press it to switch between Celsius and Fahrenheit
when the temperature data is displayed on the
LCD.
In alarm time mode, press it to turn on/off the
alarm.
In lap/split/countdown mode, press it to start or
stop the time measurement.
In lap/split Recall mode, press it to check the lap/
split records downwards.
In normal time, alarm time or countdown time
setting mode, press it to change the setting values.

Press it to turn on the backlight for 5 seconds.

1

2

3

4

5

6

7

3

2

1

4
5

1

2

1

1

0

1

2

3 (Lap)

2

1

3

4

1

2

3

1

2

3

1

2

3

Start

Lap 1

Lap 2

Lap 3

Stop

Advertising