Menu setting table (5/6), Printer operation, Mode settings [zebra – CITIZEN CL-S631 User Manual

Page 40: Emulation

Advertising
background image

2

Printer Operation

40

Top Menu

Sub Menu

Default

Menu

Remarks

Emulation Select

ZPI2

DM4

Selects DataMax

®

/Zebra

®

compatibility

DMI

DM4: DataMax

®

400

DPP

DMI: DataMax

®

IClass

ZPI2

DPP: DataMax

®

Prodigy Plus

®

ZPI2: Zebra

®

Emulation

Emulation Auto

On

On

Selects the detection of Datamax

®

and

Detect

Off

Zebra

®

emulation.

Full Auto

After Print

AutoConfigure

On

On

Optional auto configure

Off

On .... Auto configure effective.

If a peeler unit or auto-cutter is
installed, each mode is automatically
set regardless of the “function select”
setting.

Off ... Auto configure ineffective.

When a peeler unit or auto-cutter is
installed but has not been started, it is
off and the operation is selected by
“Function select”.

Function Select

Tear

Off

Selects the type of options installed and

Tear

adjusts the "paper stop" position accordingly.

Peel On*

For example, the position where the label

Cut On*

stops in "Tear" mode is different to that in
"Peel On" mode.

Cutter Action*

Backfeed

Backfeed

Cutter operating method setting

Through

Backfeed: it feeds back after each cutting
operation.
Through: when the number copied = n, the
back end of sheet 1 to n-1 passes through,
and the back end of the final page that is a
single sheet is copied and fed back.

Paper Position

0.00IN

Peel/Cut/Tear Off

The stop position can be fine tuned using

0.00mm

0.00 to 2.00 IN

this menu setting. The general stop position

0.0 to 50.8mm

is selected depending on the "Function"

Peel/Cut/Tear On

selected above.

-1.00 to 1.00 IN
-25.4 to 25.4mm

Mode/Repeat Key

Disabled

LabelSet

Repeat method selection

LastOne

LabelSet:

Disabled

Reissues multiple labels.

LastOne:

Issues only the final page.
In count case, it issues only 1 label while
continuing.

Disabled:

Makes the repeat key invalid.

Interface

RS-232C Baud

9600

115200

Sets the baud rate of the serial interface.

57600

• Interface related settings are effective

38400

after the power is turned on again.

19200
9600
4800
2400

RS-232C Parity

None

None

Sets the communication parity of the serial

Odd

interface.

Even

RS-232C Length

8 bits

8 bits

Sets the character length of the serial

7 bits

interface.

Mode Settings
[Zebra

®

Emulation]

* Effective only when the optional unit is attached.

Advertising
This manual is related to the following products: