Instructions for 120VAC/15A MAX

Single Pole Switches with

Pressure-Lock® (Push-In) &

Screw Terminals.

Pressure-Lak® terminals for use on 15 Amp
branch circuitswith No. W AWG solid copper
conductors only. Do not use on 20A
branch circuit. Screw terminals for use

with No. 12 or 10 AWG copper wire.

II Shut off

power to the
circuit at fuse
box or circuit
breaker.
Remove wall
plate and test

to be sure

power has
been
completely
disconnected.
21 Remove old
switch from

wall box and

disconnect

(i

Form wires

3/4 around

terminal

screws
(da nat
overlap).

31 For screw terminals, strip off

3/4 ■ of insulation from the ends of the

wires. Reconnectwiresto FIOT terminals
on new switch, forming wireclocl«/ise

3/4 around screw os shown.

For push-in terminals, strip off 1/2" of
insulation and insert into the push-in

terminals. NOTE; To release Push-In
wires, insert screwdriver into release slot
and pull outwirewhile applying

downward
pressure to

screwdriver.

4| Connect GREEN

or BARE

I'GROUNDING")

wire to GREEN

screw on switch
bracket.

5) Tighten oil

screw terminals

securely

to 14 in-lbs Install
switch inwall box.
Replace wall plate.
Restore power.