A

WARNING

Fire Hazard

Do Not use nonmetal, flexible duct. Do Not use metal duct smaller that four inches in diameter. Do

Not use exhaust hoods with magnetic latches. Improper air supply for exhausting may result in a

fire. Check that the exhaust system is not longer than specified. Exhaust systems longer than

specified will:

Accumulate lint

Shorten the life of the product

Reduce performance and result in longer drying times and increased energy usage.

Failure to follow these specifications may result in a fire.

Do Not exhaust dryer into a chimney, furnace cold air duct, attic or crawl space, or any other duct

used for venting. Clean the exhaust system every other year. Do Not install flexible duct under
wall, ceiling or floor materials. Accumulated lint could result in a fire or cause moisture damage.

A

WARNING

Fire Hazard

M

l

Connect dryer to a regulated gas supply. LR gas supply must not ex­

ceed a pressure of 13" water column. This must be checked by a quali­
fied person before installing the dryer. Use new, flexible tubing. Old
tubing may leak. All connections must be wrench-tightened. Do Not
check for gas leaks using an open flame. Failure to follow these instruc­
tions could result in a fire or explosion.

A

WARNING

Potential Fire Hazard

The dryer must be exhausted outside. If dryer is installed in a closet, the

dryer MUST be exhausted outside. Failure to do so increases the risk of
fire.