Filling the water heater, Venting, Caution – Kenmore POWER MISER 153.33616 User Manual

Page 14: Iùk warning, Adanger

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

ADANGER

Water temperature over 125°F
(52X) can cause severe burns
Instantfy resulting in severe injury
or death.

Children, the elderly, and the
physically or mentally disabled
are at highest riskfor scald injury.

Feel water before bathing or
showering.

Temperature limiting valves are

available.

Read instruction manual for safe

temperature setting.

The temperature-pressure relief valve must be manually
operated at least once a year. Caution should be taken to
ensure that (1) no one is in front of or around the outlet of the
temperature-pressure relief valve discharge line, and (2) the
water manually discharged will not cause any bodily injury or
property damage because the water may be extremely hot

If after manually operating the valve, it fails to completely reset

and continues to release water, immediately close the cold
water inlet to the water heater, follow the draining instructions,
and replace the temperature-pressure relief valve with a new
one.

FIGUFŒ16.

Filling the Water Heater

CAUTION

Property

Damage Hazard

Avoid water heater damage.

Fill tank with water before operating.

Never use this water heater unless it is completely full of water.
To prevent damage to the tank, the tank must be filled with

water. Water must flow from the hot water faucet before turning

“ON” gas to the water heater.

To fill the water heater with water:

• Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of
the water heater.

• Open the cold water supply valve to the water heater.

N01^: The cold water supply valve must be left open when

the water heater is in use.

• To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run

until a constant flow is obtained. This will let air out of the

water heater and the piping.

• Check all water piping and connections for leaks,

as needed.

Venting

Repair

iùk WARNING

Breathing

Hazard - Carbon Monoxide Gas

Vent dampers must be certified
in accordance with ANSI Z21.68.
Vent damper must permit proper
drafting of water heater.

Install properly sized venting.
Do not install without venting

outdoors.

Do not install without drafthood.
if common vented install In

accordance with NFPA54,

Be alert for obstructed or deterio­
rated

vent

system

to

avoid

serious injury or death.

Breathing carbon monoxide can cause brain damage or

death- Always read and understand instruction manual.

VENT DAMPERS - Any vent damper, whether it is operated
thermally or otherwise must be removed if its use inhibits proper

drafting of the water heater.

Thermally Operated Vent Dampers: Gas-fired water heaters
having thermal efficiency in excess of 80% may produce a
relatively low flue gas temperature. Such temperatures may
not be high enough to properly open thermally operated vent
dampers. This would cause spillage of the flue gases and
may cause carbon monoxide poisoning.

Vent dampers must bear evidence of certification as complying
with the current edition of the American National Standard
ANSI Z21.68 (ANSI Z21.66 & 67, respectively, cover electrically

and mechanically actuated vent dampers). Before installation
of any vent damper, consult your local Sears Service Center or

the local gas supplier for further information.