These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY-HOME (1-800-469-4663)

for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant’ Product.

improperly sealed, hot or cold supply connection,

Tighten threaded connections.

WATER LEAKS

relief valve, drain valve, or thermostat threads.

Leakage from other appliances or water lines.

Inspect other appliances near water heater.

Condensation of flue products.

Refer to CONDENSATION.

Thermal expansion in closed water system.

Install thermal expansion tank (DO NOT plug T&P valve).

LEAKING T&P VALVE

Improperly seated valve.

Check relief valve for proper operation

(DO NOT plug T&P valve).

SMELLY ODORS

High sulfate or mineral content in water supply.

Drain and flush heater thoroughly, then refill.

Bacteria in water supply.

Chlorinate or aerate water supply.

Gas control knob not positioned comectly.

Refer to LIGHTING INSTRUCTIONS.

Main gas supply off.

Turn on main gas shutoff valve.

Igniter tip more than 1/8" from pilot hood.

Adjust ignitor tip.

Thermocouple malfunction.

Replace pilot assembly.

Thermocouple TCO malfunction.

Replace pilot assembly.

Melted insulation on ignitor wire or shorting

Contact Sears Service to determine cause.

PILOT WILL NOT LIGHT

of ignitor wire.

High ambient room temperature.

Contact Sears Service to determine cause.

V\^re disconnected from spark ignitor.

Reconnect wire connector to spark ignitor.

Broken electrode or electrical wire.

Replace pilot assembly.

Piezo Ignitor generator fails to operate or

malfunctions.

Repiace Piezo Ignitor generator.

Thermocouple TCO malfunction.

Replace pilot assembly.

High ambient room temperature.

Contact a seryice agency to

determine cause.

BURNER WILL NOT

Dirty or clogged air intake screen.

Clean and reinstall air intake screen.

STAY LIT

Flame arrestor openings blocked.

Contact Sears Service to

determine cause.

Defective Gas Control.

Replace Gas Control.

Dirty pilot burner.

Clean pilot assembly.

Dirty or clogged air intake screen.

Clean and reinstall air intake screen.

PILOT OUTAGE

Thermocouple tip is not In contact with pilot flame.

insert thermocouple correctly.

Thermocouple malfunction.

Replace pilot assembly.

Thermocouple TCO malfunction.

Replace pilot assembly.

Defective Gas Control.

Replace Gas Control.

Heater not lit or thermostat not on.

Refer to LIGHTING INSTRUCTIONS.

Thermostat set too low.

Refer to TEMPERATURE REGULATION.

Heater undersized.

Reduce hot water use.

NOTENOUGH

Low gas pressure.

Contact your gas supplier.

HOT WATER

Incoming water is unusually cold.

Allow more time for heater to re-heat.

Leaking hot water pipes or fixtures.

Have plumber check and repair leaks.

High temperature limit switch activated.

Contact Sears Service to

determine cause.

WATER TOO HOT

Thermostat set too high.

Refer to TEMPERATURE REGULATION.

WATER HEATER SOUNDS

Condensation dripping on burner.

Refer to CONDENSATION.

SIZZLING - RUMBLING

Sediment or calcium in bottom of heater tank.

Clean sediment from tank. Refer to DRAINING

instructions in Maintenance section of manual.

SOOTING

improper combustion.

No adjustment available. Contact Sears Service

to determine cause.

Lack of supply air.

VENT GAS ODORS

improperly installed vent piping.

Contact Sears Service to determine cause.

Downdraft.

Poor combustion.

26