INSTALLATION INSTRUCTIONS

m

z

o

r

(A

X

GAS REQUIREMENTS (GAS MODELS ONLY)

CONNECTING GAS DRYERS

A

WARNING:

To reduce the risk of fire,

electric shock, or injury to persons when using
this appliance, follow basic precautions, including

the following:

• Gas supply requirements:

As shipped from the factory, this dryer is config­

ured for use with (NG) natural gas. It can be con­

verted for use with LP (Liquefied Propane) gas. Gas

pressure must not exceed 8 in. water coiumn for

(NG), or 13 in. water coiumn for (LP).

• A qualified service or gas company technician must

connect the dryer to the gas service. Failure to do so
can result in fire, explosion, or death.

• Isolate the dryer from the gas supply system by

closing its individual manual shutoff valve during
any pressure testing of the gas supply. Failure to do
so can result in fire, explosion, or death.

• Supply line requirements: Your laundry room must

have a rigid gas supply line to your dryer. In the
United States, an individuai manual shutoff valve
MUST be installed within at least 6 ft. (1.8 m) of the

dryer, in accordance with the National Fuel Gas
Code ANSI Z223.1 or Canadian gas instaiiation code
CSA B149.1. A 1/8 in. NPT pipe plug must be

installed. Failure to do so can result in fire, explo­

sion, or death.

• If using a rigid pipe, the rigid pipe should be 1/2 in.

IPS. If acceptable under local codes and ordinances

and when acceptable to your gas supplier, 3/8 in.
approved tubing may be used where iengths are

iess than 20 ft. (6.1 m). Larger tubing should be
used for lengths in excess of 20 ft. (6.1 m). Failure

to do so can result in fire, explosion, or death.

Connect the dryer to the type of gas shown on the
namepiate. Failure to do so can result in fire, explo­
sion, or death.

To prevent contamination of the gas valve, purge
the gas supply of air and sediment before connect­

ing the gas supply to the dryer. Before tightening

the connection between the gas supply and the
dryer, purge remaining air until the odor of gas is
detected. Failure to do so can result in fire, explosion,
or death.

DO NOT use an open flame to inspect for gas leaks.
Use a noncorrosive leak detection fiuid. Failure to do
so can result in fire, explosion, or death.

Use oniy a new AGA- or CSA-certified gas supply
line with flexible stainless steel connectors. Failure

to do so can result in fire, explosion, or death.

Securely tiqhten all gas connections. Failure to do
so can resun in fire, explosion, or death.

Use Teflon tape or a pipe-joint compound that is
insoiubie in Liquefied Petroieum (LP) gas on aii
pipe threads. Failure to do so can result in fire, explo­
sion, or death.

DO NOT attempt any disassembly of the dryer; any

disassembly requires the attention and tools of an
authorized and qualified service person or company.

Failure to do so can result in fire, explosion, or death.

Electrical Requirements for Gas Models Only

• Do not, under any circumstances, cut or remove the

third (ground) prong from the power cord. Failure to
follow this warning can result in fire, explosion, or death.

• For personal safety, this dryer must be properly

grounded. Failure to follow this warning can result in

fire, explosion, or death.

• The power cord of this dryer is equipped with a

3-prong (grounding) plug which mates with a stan­
dard 3-prong (grounding) wall outlet to minimize the

possibility of electric shock hazard from this appli­

ance. Failure to follow this warning can result in fire,
explosion, or death.

This dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker. Failure to follow this warning can result

in fire, explosion, or death.

Where a standard 2-prong wall outlet is encoun­
tered, it is your personal responsibility and obliga­
tion to have it replaced with a properly grounded

3-prong wall outlet. Failure to follow this warning can

result in fire, explosion, or death.