Warning, Installing the product, English – Canon VC-C50iR User Manual

Page 51: Using a tripod

Advertising
background image

Before You Use the Product

13

ENGLISH

Installing the Product

(Installation)
• Distance between tapped holes: 114 mm (4.49 in.)
• Tapped hole diameter: 6 mm (0.24 in.)
• Mounting plate thickness: 1 mm (0.04 in.)

Install the camera securely.

When installing the camera on the ceiling, contact your Canon dealer.
● When installing the camera on the ceiling, check that the ceiling is strong enough to

bear the weight of the camera including the installation bracket. Installation in a
weak location could result in the camera falling and causing serious injury.

● At least once a year, check for looseness in the camera installation mount. (If the

optional wide-angle converter is used, check the converter mount also.)
* The Wide-angle Converter WL-37 cannot be used on the VC-C50iR.

a

WARNING

Using a Tripod

The screw mount for a tripod is located in the center of the underside of the camera.

The permissible camera installation angles are

±20° from the horizontal. (±15°

when the optional wide-angle converter is used.)

NOTE

Less than
6.0 mm
(0.24 in.)

Mounting
screw

30 mm
(1.18 in.)
or wider

Do not overtighten the mounting screw.

If excessive force is used to tighten the
mounting screw, camera head movement
may be impeded, or other malfunctions may
result.

● Always use a tripod mounting screw that is

less than 6.0 mm (0.24 in.) in length. The use
of screws 6.0 mm (0.24 in.) long or longer
could damage the camera. Also, the tripod
seat used should be at least 30 mm (1.18 in.)
in diameter.

NOTE

Mounting plate

Screw

VC-C50iR

Screw

VC-C50i Installation

Install in a flat and stable location.

VC-C50iR Installation

Firmly tighten the 2 screws (not supplied).