Installation checklist, Check for leaks, Installation instructions (cont’d) – Kenmore POWER MISER 153.330551 User Manual

Page 16

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

VENT PIPE TO

OUTDOORS

OR CHIMNEY

Installation Checklist

BEFORE LIGHTING THE PILOT:

• Check the gas lines for leaks,

a. Use a soapy water solution, DO NOT test for gas leaks

using a match or open flame,

b. Brusn the soapy water solution on all gas pipes, joints and

fittings,

c. ChecK. for bubbling soap. This means you have a leak.

Turn “OFF” gas and make the necessary repairs.

d. Recheck for leaks.

e. Rinse oflF soapy solution and wipe dry.

• Is the new temperature-pressure relief valve properly installed

and piped to an adequate drain? See “Temperature-Pressure

Relief Valve” section.

• Are the cold and hot water lines connected to the water

heater correctly? See “Water Piping” instructions in the

“Installation Instructions” section,

• Is the water heater completely filled with water? See “Filling”

insrructions in the “Installation Instructions”.

• Will a water leak damage anything? See the “Facts to

Consider About the Location” section.

• Is there proper clearance between the water heater and any­

thing that might catch fire? See the “Facts to Consider About

the Location” section.

• Do you have adequate ventilation so that the water heater

will operate properly? See “Combustion Air and Ventilation”

in the “Facts to Consider About the Location” section,

• Is the draft hood vent piping properly secured? See “Venting”

instructions in the “Installation Instructions” section.

• Is there proper clearance between the vent pipe and anything

that might catch on fire? See “Venting" instructions in the

“Installation Instructions” section,

• Is the vent pipe properly sloped and does the vent terminate

outdoors? See “Venting” instructions in the “Installation

Instructions” section.

• Do you need to call your gas company to check the gas pipe

and its hookup?

Installation Instructions (cont’d)

CHECK FOR LEAKS

Be sure ro check all your gas pipes for leaks before lighting your

water heater. Use a soapy water solution, not a match or open

flame. Check the factory gas fittings after pilot is lit and gas con­

trol knob is still in “PILOT” position. Then, check the fittings

when the main burner is turned “ON”. Use a soapy water solu­

tion for this, too.

V

cold

UNION SHUTOFF VALVE

STEMPERATO RE­

PRESSURE

RELIEF VALVE

DISCHARGE

PIPE

(Do not cap or plug)

SHUTOFF

VALVE

TEE

DRIP LEG

(SEDIMENT '

TRAP)

6 INCH AIR GAP

■wnoiMTie iiiMNM MMTpt

hmtw

MOOB.NUHHn

WATER №ATER

BQUIFPe)

FOR MFUr

RECOWirr

U.S.OAL

ANSZ21.10

3fMM. MJHÉEH

1 1 1

QM BTUMR.

(MUHR.

OAS PHESSWEIN W.C.

«.auTMAiM lÉMaram

_____ J 1

w£. W.C.

MODEL RATING PLATE

16

Advertising