Choose your exhaust installation type

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.

B

Plan Ifent Ssistem

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for

................ your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

A. Dryer

B. Elbow

a Wall

D. Exhaust hood

E. Clamps

E Rigid metal or flexible metal vent

G. Vent

length necessary to connect elbows

H. Exhaust outlet

Optional exhaust installations

M

Fire

Hazard

Cover unused exhaust holes with the

following

kit;

279818 (white)

Contact your local dealer.

Failure to follow these instructions can result in death,

fire, electrical shock, or serious injury.

This dryer can be converted to exhaust out the right side, left
side, or through the bottom. Contact your local dealer to have the
dryer converted.

A. Standard rear offset exhaust Installation

B. Left or right side exhaust installation

C. Bottom exhaust installation (not an option

with pedestal installations)

A. Over-the-top installation (also available with one

offset elbow)

B. Periscope Installation

NOTE: The following kits for close clearance alternate
installations are available for purchase. For further information,
please cal 11-800-4-MY-HOME® (1-800-469-4663).

■ Over-the-Top Installation:

Part Number 26-49900

■ Periscope Installation (For use with dryer vent to wall vent

mismatch):

Part Number 26-49901 - Less than 5" (12.7 cm) mismatch

Part Number 26-49908 - 5" (12.7 cm) to 18" (45.72 cm)
mismatch

Part Number 26-49904 - 18" (45.72 cm) to 29" (73.66 cm)
mismatch

Part Number 26-49905 - 29" (73.66 cm) to 50" (127 cm)
mismatch

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.

Determine vent path

Select the route that will provide the straightest and most
direct path outdoors.

Plan the installation to use the fewest number of elbows and

turns.

When using elbows or making turns, allow as much room as
possible.

Bend vent gradually to avoid kinking.

Use the fewest 90° turns possible.