Dryer gas pipe

vmmmfmmmiffmnmmm/mmmmmmm.

The gas pipe that comes out through the rear of your dryer

has a %" male pipe thread.

A. Vs" NPTgas supply line

B. W NPT dryer pipe

*NOTE: If the dryer is mounted on a pedestal, the gas pipe height

must be an additional 10" (25.4 cm) from the floor. For a garage
installation, the gas pipe height must be an additional
18" (46 cm) from the floor.

Venting Reqyiremerts

A WARNING

M

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal toil vent.

Failure to follow these instructions can result in death
or fire.

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.

■ Replace any plastic or metal foil vent with rigid or flexible

heavy metal vent.

■ Review Vent system chart. Modify existing vent system if

necessary to achieve the best drying performance.

If this is a new vent system

Vent material

■ Use a heavy metal vent. Do not use plastic or metal foil vent.

■ 4" (10.2 cm) heavy metal exhaust vent and clamps must be

used. DURASAFE'^'^ venting products are recommended.

4" (10.2 cm) heavy metal exhaust vent

DURASAFE'^'^ vent products can be purchased from your
dealer. For further information, please call

1-800-4-MY-HOME® (1 -800-469-4663) or visit our website at

www.sears.com.

Rigid metal vent

■ For best drying performance, rigid metal vents are

recommended.

■ Rigid metal vent is recommended to avoid crushing and

kinking.

Flexible meta! vent

■ Flexible metal vents are acceptable only if accessible for

cleaning.

■ Flexible metal vent must be fully extended and supported

when the dryer is in its final location.

■ Remove excess flexible metal vent to avoid sagging and

kinking that may result in reduced airflow and poor
performance.

■ Do not install flexible metal vent in enclosed walls, ceilings or

floors.

Elbows

45° elbows provide better airflow than 90° elbows.

Good

Better