Installation Requirements

See Figure 17. Inspect window track, sash, and sill.

Ensure window will bear weight of air conditioner for

extended period of time. Measure width of window
opening to be sure installation kit will fit. Air conditioner
is designed for windows 28“ to 42“ wide. Ensure lower
left inside corner of window is within 6‘ of appropriate
electrical outlet.

NOTE: Installation kit is designed for most double-hung

windows that do not have storm windows

installed. If stoim window is installed or if

installation is in mobile home, window sill may

need modification. See procedure for Storm

Window Modification or for Mobile Home
Window Modification.

Figure 17. Typical Double-Hung Window

1. Window frame
2. Window track

3. Outdoor sash

4. Indoor sash

5. Windowsill (indoor)

Storm Window Modification

See Figure 18. If storm window frame does not allow
adequate clearance (V4" required) to window sill, remove
frame or create clearance by adding wood strip at 1

wide along entire width of sill. Fasten wood strip to sill

with 3 countersunk wood screws (not provided). Use
countersunk screws to ensure a smooth surface for
mounting kit.

Mounting kit can now be installed.