Installation

installing Room Air Conditioners

Proper installation of a room air conditioner helps

ensure trouble-free operation. Improper installation can

result in problems ranging from excessive noise to

property or equipment damage.

Installation requires some mechanical experience and

aptitude. Depending upon installer’s knowledge and
skill, installation of a room air conditioner can take
between 1 and 3 hours. Professional installation,
performed by authorized Sears technicians, is available.
Contact a local Sears store or call 1-800-4-MY-HOME to
obtain an estimate and schedule an installation.

Before Beginning Any Installation

• Carefully read all installation instructions. Make sure

each step or procedure is understood and any special
considerations are taken into account.

• Before starting installation, assemble all tools,

hardware, and supplies needed. Some items may

need to be purchased locally.

• After deciding where to install unit, carefully examine

location—both inside and outside. Note any potential

obstacles or problems. Choose a more suitable

location, if necessary.

Electrical Requirements

A

WARNING

To avoid risk of personal injury or death due to
electrical shock:

• DO NOT remove warning tag from power cord.

• Electrical grounding is required on all air

conditioners.

• Check with a qualified electrician if you are not

sure intended electrical outlet is properly
grounded.

- DO NOT ground to gas line.

- DO NOT ground to cold water pipe if pipe is

interrupted by plastic, non-metallic gaskets, or
other insulating (non-conducting) materials.

• DO NOT modify plug on power cord. If plug does

not fit electrical outlet, have a matching outlet
installed by a qualified electrician.

■ DO NOT have a fuse in the neutral or ground

circuit. A fuse in the neutral or ground circuit
could result in an electrical shock.

- DO NOT use an extension cord with this device.

• DO NOT use an adapter plug with this device.

• Observe all local codes and ordinances.

Grounding Instructions

For safety, air conditioner must be grounded. All air

conditioners have power supply cord with three-prong
grounding plug. To minimize possible electrical shock
hazard, power cord must only be plugged into matching

grounding wall receptacle in accordance with National
Electrical Code (and any applicable local codes and
ordinances). If appropriate grounding-type wall
receptacle Is not available, have properly grounded wall
receptacle installed by qualified electrician.

If codes permit and separate grounding wire is used,
have qualified electrician determine if grounding path is

adequate and uninterrupted by plastic, non-metallic

gaskets, or other insulating (non-conductive) materials.

Electrical Connection

A separate (dedicated) circuit is required for units

labeled “Use on Single Outlet Circuit Only.” Devices
covered in this manual require a 60Hz supply. Refer to
unit nameplate for exact voltage requirements. Voltage
requirements can also be determined by type of plug on

ai r cond itioner. See Table 1.

Tablet. Air Conditioner Power Requirements

Unit Plug

Receptacle

Circuit Rating, Voltage

Type

Required

Breaker, Time

Rating On

Delay Fuse

Nameplate

NEMA No. 5-15P NEMA No. 5-15R 125V-15AMP

115V

©

(S)

NEMA No. 6-1SP NEMA No. 6-15R 250V-15AMP

23(V208V rated

o

at

12

amperes or

less

NEMA No. 6-20P NEMA No. 6-aOR 250V-20AMP

23<V2oeVraled
over 12 amperes.

f

but not mora than

16 amperes

NEMA No. 6-30P NEMA No. 6-30R 250V-30AMP

206V rated over
16 amperes, but

not more than

(

*

)

24 amperes

Do not use an extension cord. If air conditioner power
supply cord does not reach intended wall receptacle,
have qualified electrician install or move appropriate
receptacle closer to unit.

Do not use an adapter plug. If intended wall receptacle
does not match plug on air conditioner, have qualified
electrician replace receptacle with correct type.