ERROR CODES

WIRELESS REMOTE MONITORING STATION

Error
Code

EO

E1

w

e

F

Error Type

Temperature
Sensor

Defrost
Sensor

Humidity
Sensor

Pump Drain

Possible Causes

1. Sudden change

in the

surrounding
temperature.

2. Faulty sensor.

. Improper

bucket
installation.

. Blockage to

drain hose
system.

. Back flow of

water through

pump drain
hose.

. Improper pump

drain hose

installation.

. Faulty drain

pump.

Corrective Actions

1. Unplug the dehumidifier.

2. Check the surrounding area for possible

reasons for sudden temperature changes.

3. Wait 30 minutes before plugging the

dehumidifier back in and resuming normal
operation.

4. If the “Error” is still indicated, please

contact your nearest service center.

1. Unplug the dehumidifier.

2. Remove the bucket.
3. Check to make sure that there is nothing

blocking the connection at the base of the
pump or the bucket.

4. Reinstall the bucket, taking care that it is

installed properly.

5. Check to make sure that the pump drain

hose is not crimped or blocked.

6. Check to make sure that the pump drain

hose is not both under water and sitting at
a height above the dehumidifier - this can
cause a “back flow” of water from the hose
to the dehumidifier.

7. Remove and reinstall the pump drain hose,

taking care that the pump drain hose is

installed properly.

8. Plug the dehumidifier in and restart
9. If the “E3” error is still indicated, please

contact your nearest service center.

The remote monitoring station is a receiver
with a receiving range of only 330 feet in
open air with no obstructions. Actual receiving
range will vary depending on what is in
the path of the signal transmitted from the
dehumidifier unit. Each obstruction (roof,
walls, floors, ceilings, thick trees, etc.) will
effectively cut signal range in half.

Example: The wireless remote monitor with
a 330-foot range is mounted on an interior

wall or placed on a countertop so the signal
from the dehumidifier has to pass through one

basement wall, across the 10-foot width of the
room through the room’s other wall and then
through the floor to the room upstairs where
the receiver is located. The first wall

will reduce the range to 165 feet, and the
second wall will reduce the range to 87 feet.

Factoring in the 10-foot room, this leaves
a maximum of 77 feet of remaining signal
range. Passing up through the floor has now
reduced the effective range to 38 feet.

Typically this allowance is enough for most
frame-constructed homes; however certain

materials can reduce range even further.
Metal siding, stucco, and some types of

glass can reduce signal range by as much
as 75% compared to the 50% reduction
typical of most obstructions. It is possible
to receive a signal through these materials;
however maximum range will be much less,
due to their tendency to absorb or reflect
a much larger portion of the dehumidifier’s
signal.

NOTE: You may have to move the monitor
closer to the main unit if it is not receiving a
proper signal following set-up procedures.

PRODUCT SPECIFICATIONS

Classification

Spec

Remark

Model

251.90701

Power Supply

AC 115V/60(Hz)

Moisture Removal

70 Pint(33.1 liters)

24-Hour Period

Control Type

Electronic

Refrigerant

R410A/11.29 oz.

320g

Humidity
Display

Humidity Setting: 35%-70%
Display Range: 20%-90%

5% Increments

1% Increments. Current Humidity.

Temperature

Display

Display Range: Lo, 36-99°F, Hi

1° F Increments. Current Temp.

Display Range: Lo, 2-37°C, Hi

1° C Increments. Current Temp.

Timed Shut-off

Setting Range: 1Hr-12Hr

1 Hour Increments

Fan Motor Speed

3 Speeds

Auto/High/Low

Dimensions

15.74x25.59x13.6 in

400x650x346mm

Net Weight

49 lbs

22.3Kg

Operating Temp.

36^-99^

Drain Pump

12V DC

Pump Drain Hose

.25 in X 18 ft

6.35x5,486mm

Setup Guide

Insert the batteries in the monitor. After

the batteries are inserted, the Monitoring
Station will start receiving signal data from
the dehumidifier: temperature, humidity, etc.
should be displayed on the monitor’s screen.

If this doesn't happen after 2 minutes, check

the dehumidifier to make sure it is operating
properly. Remove the batteries from the

monitor, wait a minute, then replace.

Batteries

iiBi <

OS: 00

O

111

Oj^

TEMPEi?ATUi?E

ijrf

Ou

(jn

IO

-

(3 Receiver On

Battery Strength

Sound Aiert

Time of Day

Fan On

O

Bucket Fuii

O

Pump On

O Temperature

O Humidity

O

Waii Hanger

O Set Button

(3 Minus

QPIus

O Sound On/Off

10

11

Advertising