Natural gas safety instructions – Kenmore ELITE 141.1668 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Natural Gas Safety Instructions

Figure 1 (Natural gas model only)

IMPORTANT: your Kenmore Natural Gas Grill cannot
be converted to use LP Gas. Attempting to do so
is extremely hazardous and will also void the grill

warranty.

• Your natural gas grill is designed to operate on

natural gas only, at a pressure of 7" water column
(W.C.) (1/4 psi or 1.75 kpa), regulated at the
residential meter. Check with your gas utility
company for local gas pressure and with your
local municipality for building code requirements. If
your residential gas line pressure has not been

regulated to 7" W.C., contact your local gas utility
company for professional assistance.

• It is recommended that a Shutoff Valve be installed

at the gas supply source outdoors. Install at a point
after the gas pipe exits the outside wall and before
the quick-disconnect hose, or install it at the point

before the gas line piping enters the ground.
See Fig. 1.

• Pipe sealing compound or pipe thread tape resistant

to the action of natural gas must be used on all male
pipe threads when making the connection.

GAS SUPPLY

• Disconnect your gas grill from fuel source when

the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must

be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 pst (3.5kpa).

• Turn off your gas grill when the gas supply is

being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).

Advertising