Troubleshooting (continued) – Kenmore 146.1622201 User Manual

Page 24

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Troubleshooting (continued)

Problem

Possible Cause

Burner(s) will not light

using ignitor.

(See Electronic ignition

Troubleshooting also)

ELECTRONIC IGNITION:

• No spark, no ignition noise.

• No spark, some ignition noise.

• Sparks, but not at electrode or at full

strength.

• See Section I of Electronic Ignition System.

• See Section II of Electronic Ignition System.

• See Section III of Electronic Ignition System.

Burner(s) will not match

light.

• See

“GAS ISSUES:”

on previous page.

• Match will not reach.

• Improper method of match-lighting.

• Use long-stem match (fireplace match).

• See “Match-Lighting” section of Use and Care.

Sudden drop in gas

flow or low flame.

• Out of gas.

• Excess flow valve tripped.

• Vapor lock at coupling nut/LP cylinder

connection.

• Check for gas in LP cylinder.

•Turn off knobs, wait 30 seconds and light grill. If flames are still low,

turn off knobs and LP cylinder valve. Disconnect regulator.

Reconnect regulator and leak-test. Turn on LP cylinder valve, wait

30 seconds and then light grill.

•Turn off knobs and LP cylinder valve. Disconnect coupling nut from

cylinder. Reconnect and retry.

Flames blow out.

• Fligh orgusting winds.

• Low on LP gas.

• Excess flow valve tripped.

• Turn front of grill to face wind or increase flame height.

• Refill LP cylinder.

• Refer to “Sudden drop in gas flow” above.

Flare-up.

• Grease buildup.

• Excessive fat in meat.

• Excessive cooking temperature.

• Clean burners and inside of grill/firebox.

• Trim fat from meat before grilling.

• Adjust (lower) temperature accordingly.

Persistent grease fire.

• Grease trapped by food buildup around

burner system.

•Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in position

and let fire burn out. After grill cools, remove and clean all parts.

Flashback...

(fire in burner tube(s)).

• Burner and/or burner tubes are blocked.

• Turn knobs to OFF. Clean burner and/or burner tubes. See burner

cleaning section of Use and Care.

Unable to fill LP

• Some dealers have older fill nozzles

• The worn nozzles don’t have enough “bite” to engage the valve. Try

cylinder.

with worn threads.

a second LP dealer.

One burner does

not light from other

burner(s).

• Grease buildup or food particles in end(s)

of carryover tube(s).

• Clean carry-over tube(s) with wire brush.

24-640-01303702-3-58