Chromalox PQ431 User Manual

Installation, operation, Type chtv horizontal vaporizers for dowtherm, Therminol

Advertising
background image

(Supersedes PQ431)

PQ431

CHTV

161-058058-001

JULY, 1983

4

and

Installation, Operation

RENEWAL PARTS IDENTIFICATION

Type CHTV Horizontal Vaporizers for Dowtherm

®

,

Therminol

®

and Other Organic Fluids

(Temperatures to 750°F at 150 psi, 15 kW thru 300 kW)

© 2010 Chromalox, Inc.

Specifications & Dimensions

System Model Number and Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Serial Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Customer’s Name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Customer’s Order Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

National Board Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ampere*

Model Number

Dimensions

Weight

Oil &

Weather-

Explosion-

(In.)

(Lbs.)

Standard

Dust Tight

resistant

resistant

Operating

w/o

kW

BTUH

240V

480V

NEMA I

NEMA XII

NEMA IV

Class1, Group D

Volume

L

W

H

Controls

15

51,180

36.0

18.0

CHTV-316-15

CHTVO-316-15

CHTVW-316-15

CHTVX-316-15

15.7

80

36

50

600

20

68,240

48.1

24.0

CHTV-316-20

CHTVO-316-20

CHTVW-316-20

CHTVX-316-20

19.4

94

36

50

700

25

78,500

60.1

30.1

CHTV-316-25

CHTVO-316-25

CHTVW-316-25

CHTVX-316-25

23.6

110

36

50

825

30

102,360

72.2

36.1

CHTV-316-30

CHTVO-316-30

CHTVW-316-30

CHTVX-316-30

27.2

124

36

50

925

40

136,480

96.2

48.1

CHTV-316-40

CHTVO-316-40

CHTVW-316-40

CHTVX-316-40

35.6

156

36

50

1175

50

157,000

120.3

60.1

CHTV-316-50

CHTVO-316-50

CHTVW-316-50

CHTVX-316-50

43.5

186

36

50

1400

40

136,480

96.2

48.1

CHTV-624-40

CHTVO-624-40

CHTVW-624-40

CHTVX-624-40

75.0

95

48

60

1200

50

157,000

120.3

60.1

CHTV-624-50

CHTVO-624-50

CHTVW-624-50

CHTVX-624-50

106.0

111

48

60

1450

60

204,720

144.3

72.2

CHTV-624-60

CHTVO-624-60

CHTVW-624-60

CHTVX-624-60

137.0

125

48

60

1600

75

235,500

180.4

90.2

CHTV-624-75

CHTVO-624-75

CHTVW-624-75

CHTVX-624-75

168.0

149

48

60

1900

100

341,200

240.6

120.3

CHTV-624-100

CHTVO-624100

CHTVW-624-100

CHTVX-624-100

218.0

187

48

60

2350

100

341,200

240.6

120.3

CHTV-1230-100

CHTVO-1230-100

CHTVW-1230-100

CHTVX-1230-100

218.0

111

54

66

2400

125

392,500

150.4

CHTV-1230-125

CHTVO-1230-125

CHTVW-1230-125

CHTVX-1230-125

222.0

129

54

66

2700

150

511,800

180.4

CHTV-1230-150

CHTVO-1230-150

CHTVW-1230-150

CHTVX-1230-150

263.0

149

54

66

3100

175

549,500

210.5

CHTV-1230-175

CHTVO-1230-175

CHTVW-1230-175

CHTVX-1230-175

300.0

167

54

66

3500

200

682,400

240.6

CHTV-1230-200

CHTVO-1230-200

CHTVW-1230-200

CHTVX-1230-200

340.0

187

54

66

3950

225

767,700

271.0

CHTV-1836-225

CHTVO-1836-225

CHTVW-1836-225

CHTVX-1836-225

379.0

149

60

72

4600

250

853,000

301.0

CHTV-1836-250

CHTVO-1836-250

CHTVW-1836-250

CHTVX-1836-250

417.0

162

60

72

5200

275

938,300

331.0

CHTV-1836-275

CHTVO-1836-275

CHTVW-1836-275

CHTVX-1836-275

455.0

175

60

72

5600

300

1,023,600

361.0

CHTV-1836-300

CHTVO-1836-300

CHTVW-1836-300

CHTVX-1836-300

490.0

187

60

72

6000

Manufacturing

Data –

*All amperes based on 3ph 60 cycle power.

Sight Glass

Hartford Loop

Level Switch

Vent

W

L

H

Inspection Ports (2)

Spare or Fill

ASME Relief Valve

Pressure Gage

Heater Terminal Cover