ice and Adjustment (cont’d)

7. Disconnect the two wires on the element and unscrew the

old clement from the tank.

8. Clean the area around the element opening. Remove any

sediment from or around the clement opening and inside
the tank.

9. If you arc cleaning the element you have removed, do so by

scraping or soaking in vinegar or a de-liming solution.

AWARNING

Replacement elements must (I) be the same voltage and
(2) no greater wattage than listed on the model rating
plate affixed to the water heater.

10. A new gasket should be used in all cases to prevent a possi­

ble water leak. (Sec Element Gasket in the Parts Order List
Chart). Place the new clement gasket on the thread side of
the cleaned or new clement and screw into tank, securing
tighdy using an element wrench.

11. Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front

of the water heater.

12. Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open
when the water heater is in use.

13. To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run
until a constant flow is obtained. This will let air out of the

water heater and the piping.

ACAUTION

Never use this water heater unless it is completely full of

water. To prevent damage to the tank and heating ele­

ment, the tank must be filled with water. Water must

flow from the hot water faucet before turning “ON”

power.

14.

15.

Check element for water leaks. If leakage occurs, tighten
element or repeat steps 2 and 3, remove eiement and reposi­
tion gasket. Then repeat steps 10 through 14.

Reconnect the two wires to the element and then check to
make sure the thermostat remains firmly against the surface
of the tank.