BELT OR BRUSHROLL REMOVAL AND REPLACEMENT

A

WARNING

Electrical Shock and Personal
Injury Hazard

Disconnect electrical supply

before servicing or cleaning

the unit. Failure to do so could

result in electrical shock or
personal injury from vacuum

cleaner suddenly starting.

TO REMOVE BELT

Lay cleaner flat and flip cleaner to expose

nozzle base. To remove nozzle guard, slide

Jock A to unlock position, to the left. Then
depress lock B to unlock nozzle guard.

Rotate/pivot the
nozzle guard and
pull off

® Lift and remove

brushroil. Dispose
of old belt.

TO REPLACE BELT

OR BRUSHROLL

Slide belt onto motor
shaft.

Place new belt in area
of brushroil without
bristles.

With new belt in place,

pull and slide brushroil
into nozzle making

sure that the brushroil
end caps are in the
correct orientation (see
diagram for end cap
orientation). Rotate
brushroil manually

to make sure belt is
properly aligned.

Secure by aligning
the three (3) tabs
in the base slots.

To reattach nozzle
guard, rotate/pivot
back Into position.

To secure nozzle
guard, push lock B
down to lock position.
Slide lock A into lock
position, to the right.