Service Tech Information

MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the vaive motor,

brine tank fiii, brine draw, regeneration flow rates, and
other controiier functions. Aiways make the initial
checks, and the manual initiated diagnostics.

NOTE: The faceplate display must show a steady

time (not flashing). If an error code shows, first

press the SELECT button to enter the diagnostic

display.

1. Press the REGENERATiON button and hoid in for 3

seconds. *RECHARGE and Fiii begin to flash (or
ciean backwash begins, if set) as the softener enters
the fiii cycie of regeneration.

*

NOTE: If the CLEAN feature is set to ON, a clean­

ing backwash (CLEAN and Bkwsh or Rinse flashes

in the display, along with the minutes of the clean

cycle remaining), precedes the recharge.

2. When FiLL is on steady, remove the brineweii cover

and, using a fiashiight, observe fiii water entering the
tank.

3. if water does not enter the tank, iook for an obstruct­

ed nozzie, venturi, fiii flow piug, brine tubing, or brine
vaive riser pipe.

CYCLE FLOW RATES (GALLONS PER MIN.)

FiLL (flow to sait storage tank)

0.3 (1.1 iiters)

BRiNiNG (flow to drain)

.22 (.83 iiters)

BRiNE RiNSE (flow to drain)

.15 (.57 iiters)

MAX. BACKWASH (flow to drain)

2.0 (7.6 iiters)

MAX. FAST RiNSE (flow to drain)

2.0 (7.6 iiters)

4. After observing fiii, press the REGENERATiON but­

ton to move the softener into brining. A siow flow of
water to the drain wiii begin. Verify brine draw from
the brine tank by shining a fiashiight into the brineweii
and observing a noticeabie drop in the iiquid ievei.

NOTE: Be sure a salt bridge is not preventing water

with salt contact.

5. if the softener does not draw brine:

• nozzie and/or venturi dirty or defective.
• nozzie and venturi not seated properiy on gasket
• restricted drain (check drain fitting and hose)
• defective nozzie and venturi seai
• other inner vaive defect (rotor seai, rotor & disc,

wave washer, etc.)

NOTE: If water system pressure is low, an elevated

drain hose may cause back pressure, stopping

brine draw.

Brine Valve

FIG. 57

6. Again press REGENERATiON to move the softener

into backwash. Look for a fast flow of water from the

drain hose.

7. An obstructed flow indicates a piugged top distributor,

backwash flow piug or drain hose.

8. Press RECHARGE to move the softener into fast

rinse. Again iook for a fast drain flow. Aiiow the sof­

tener to rinse for a few minutes to flush out any brine
that may remain in the resin tank from the brining
cycie test.

9. To return the softener to service, press REGENERA­

TiON once more.

Questions? Call The Kenmore Water Line 1-800-426-9345