¡mum 3 ft (91 cm)

12 in. {30 cm)

from soffit

Mitiimym

7 ft. (2.3 m

above

public sidewalk

or paved
driveway

(see footnote

2 )

Minimum''

12 in. (30 cm)

from sides of

permanentiy

closed window

Minimum 4 ft. (1.2 m)

from side of window

that may be open

Minimum 12 in. (30 cm) above

window or door that may be open

Minimum 4 ft. (1.2 m)

below a window that

may be open

Minimum 4 ft. (1.2 m)

from side of window

that may be open

Minimurn 3 ft (91 cm) within a

height of 15 ft. (4.6 m) above

meter/regulatof assembiy

Minimum 3 ft ( 91 cm ) clearance

to service regulator vent outlet

Mlnimiim 12 in. (30 cm)

under veranda, porch,

deck or balcony

(see footnote 1)

Minimum

3 ft. (91 cm)

above a

mechanical air

supply inlet

within 10 ft (3 m)

horizontally

'Minimum 4 ft. (1.2 nt)

below or side of, 12 in. (30 cm)

above non moohanicai air

supply inlet into building

or combustion air inlet

to another appliance

VENT TERMINAL (X) AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

1. Permitted only if veranda, porch, deck or balcony is fully opened on a minimum of two sides beneath the floor,

2. A vent shall not terminate above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

FIGURE 23.

This unit can vent through 2", 3" or 4" nonmetalSic pipe and fittings.

The vent pipe installation can be started from either the blower discharge
or the termination wall. Keep in mind the total vent system (pipe and
elbows) when installing the vent system, see VENTING AND

INSTALLATION AND MAXIMUMVENTLENGTHS, page 17.

The vent terminal should be kept as close as possible to the outside
wall, but you need to allow at least 1.5" (3.8 cm) of pipe past the wall,
for the wall flange and vent terminal to mount on the pipe.

Before the vent terminal is installed, caulk (not supplied) around the pipe
on the exterior wall and install the optional wall flange. The flange can be
held to the outside wall by placing some of the caulking on the back of the

flange. The wall flange is supplied for decorative purposes only and is
not a requirement for the vent termination (if not needed by the installer).

VERTiCAL VENT THROUGH ROOF_________________

This unit is approved for venting through the roof with the type vent
terminal that is included with the unit. A proper flashing or “BOOT”
should be used to seal the pipe where if exits the roof.

The total vent system should not exceed that which is specified, see
VENTING AND INSTALLATION, page 17,

Ail of the pipe should be secured as per the instructions in the instructions

in the VENTING AND INSTALLATION, page 17.

vertical

VENT TERMINATION RESTRICTIONS

1. Minimum of twelve 12" (30.5 cm) above the roof or twelve 12"

(30.5 cm) above the anticipated snow level. Provide proper support

for all pipe protruding through the roof,

VENT

TERMINAL

•ALL PIPE PROTRUDING THROUGH THE ROOF

SHOULD BE PROPERLY SUPPORTED.

FIGURE 25.

2.

4'

(1.2 m) from or T (0.3 m) above any gable, dormer, or other roof

structure with access to interior of building (i.e.-vent, window etc.).

3. 3' (0.9 m) above any forced air inlet located within 10' (3.0 m).

19