Kenmore THE ECONOMIZER 153.33205 User Manual
Page 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Ш т
¡mum 3 ft (91 cm)
12 in. {30 cm)
from soffit
Mitiimym
7 ft. (2.3 m
above
public sidewalk
or paved
driveway
(see footnote
2 )
Minimum''
12 in. (30 cm)
from sides of
permanentiy
closed window
Minimum 4 ft. (1.2 m)
from side of window
that may be open
Minimum 12 in. (30 cm) above
window or door that may be open
Minimum 4 ft. (1.2 m)
below a window that
may be open
Minimum 4 ft. (1.2 m)
from side of window
that may be open
Minimurn 3 ft (91 cm) within a
height of 15 ft. (4.6 m) above
meter/regulatof assembiy
Minimum 3 ft ( 91 cm ) clearance
to service regulator vent outlet
Mlnimiim 12 in. (30 cm)
under veranda, porch,
deck or balcony
(see footnote 1)
Minimum
3 ft. (91 cm)
above a
mechanical air
supply inlet
within 10 ft (3 m)
horizontally
'Minimum 4 ft. (1.2 nt)
below or side of, 12 in. (30 cm)
above non moohanicai air
supply inlet into building
or combustion air inlet
to another appliance
VENT TERMINAL (X) AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
1. Permitted only if veranda, porch, deck or balcony is fully opened on a minimum of two sides beneath the floor,
2. A vent shall not terminate above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
FIGURE 23.
This unit can vent through 2", 3" or 4" nonmetalSic pipe and fittings.
The vent pipe installation can be started from either the blower discharge
or the termination wall. Keep in mind the total vent system (pipe and
elbows) when installing the vent system, see VENTING AND
INSTALLATION AND MAXIMUMVENTLENGTHS, page 17.
The vent terminal should be kept as close as possible to the outside
wall, but you need to allow at least 1.5" (3.8 cm) of pipe past the wall,
for the wall flange and vent terminal to mount on the pipe.
Before the vent terminal is installed, caulk (not supplied) around the pipe
on the exterior wall and install the optional wall flange. The flange can be
held to the outside wall by placing some of the caulking on the back of the
flange. The wall flange is supplied for decorative purposes only and is
not a requirement for the vent termination (if not needed by the installer).
VERTiCAL VENT THROUGH ROOF_________________
This unit is approved for venting through the roof with the type vent
terminal that is included with the unit. A proper flashing or “BOOT”
should be used to seal the pipe where if exits the roof.
The total vent system should not exceed that which is specified, see
VENTING AND INSTALLATION, page 17,
Ail of the pipe should be secured as per the instructions in the instructions
in the VENTING AND INSTALLATION, page 17.
vertical
VENT TERMINATION RESTRICTIONS
1. Minimum of twelve 12" (30.5 cm) above the roof or twelve 12"
(30.5 cm) above the anticipated snow level. Provide proper support
for all pipe protruding through the roof,
VENT
TERMINAL
•ALL PIPE PROTRUDING THROUGH THE ROOF
SHOULD BE PROPERLY SUPPORTED.
FIGURE 25.
2.
4'
(1.2 m) from or T (0.3 m) above any gable, dormer, or other roof
structure with access to interior of building (i.e.-vent, window etc.).
3. 3' (0.9 m) above any forced air inlet located within 10' (3.0 m).
19