Kenmore ELITE 153.33264 User Manual

Page 32

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

10. Replace the outer door (see item K page 10).

Door Gasket Burner

^ /

Slot

-

/

Viewport

/

"

Manifold Tab

FIGURE 40.

Removing and Replacing the Gas Control

Valve/Thermostat

IMPORTANT: Use only factory authorized replacement parts.
Removing the Gas Control Valve/Thermostat:

1. Set the gas control valve/thermostat to its lowest setting by

first depressing the COOLER © and HOTTER® buttons
together and hold for 1 second. Then press the COOLER®

button until the VAC indicator light appears (Figure 32).

2.

Unplug the water heater from the wall outlet.

3. Turn off the gas supply to the water heater at the manual gas

shut-off valve. This valve is typically located beside the water
heater. Note the position of the shut-off valve in the open/on
position then proceed to turn it off (Figure 12).

4.

Drain the water heater. Refer to the section of “Draining and
Flushing” section and follow the procedure.

5. Disconnect the the flame sense/hot surface igniter wire,

power supply transformer, pressure switch/fan and display
connector wires from the thermostat (Figure 35). Disconnect
the manifould tube at the thermostat (Figure 35).

6.

Refer to “Gas Piping” section (Figure 12) and disconnect

the ground joint union in the gas piping. Disconnect the
remaining pipe from the gas control valve/thermostat.

7. To remove the gas control valve/thermostat, thread a correctly

sized pipe into the inlet and use it to turn the gas control valve/
thermostat (counterclockwise.) Do not use pipe wrench or
equivalent to grip body. Damage may result, causing leaks.

Do not insert any sharp objects into the inlet or outlet connections.
Damage to the gas control valve/thermostat may result.

2.

Reconnect the gas piping to the gas control valve/

thermostat. NOTE: Use an approved Teflon tape or pipe
compound on the gas piping connections.

3. Reconnect the manifold tube, flame sense/hot surface igniter

wire, power supply transformer, pressure switch/fan and
display connector wires (Figure 35).

4.

Fill the tank completely with water. NOTE: To purge the
lines of any excess air, keep the hot water faucet open for 3
minutes after a constant flow of water is obtained.

5. Turn on the gas supply and test the gas supply connections

by brushing on an approved noncorrosive leak detection
solution. IMPORTANT: Do Not splash solution onto the
electrical connections. Bubbles forming indicate a leak.
Correct any leak found.

6. Check the operation of the burner by following the lighting

instructions on the front of the water heater. With the burner
lit, check the gas control valve/thermostat supply line,
manifold tube connections for leaks.

7. Verify proper operation and then replace the outer door.

TEFLON® is a registered trademark of E.i. Du Pont De Nemours and Company

Replacing the Gas Valve:
1. To replace the gas control valve/thermostat, reassemble

in reverse order. When replacing the gas control valve/

thermostat, thread a correctly sized pipe into the inlet and
use it to turn the gas valve (clockwise.) DO NOT OVER
TIGHTEN or damage may result. NOTE: Use an approved
TEFLON® tape or pipe compound only on the threaded
section of the gas control valve/thermostat that screws into
the tank.

32